Precautions
Correct Use
Mounting
With the Roller Lever-type Enclosed Switches, the roller arm has
been temporarily tightened prior to shipment, so that its position may
be adjusted later. When mounting the Switch, be sure to re-tighten
the roller arm so as to prevent it from becoming loose during opera-
tion.
To adequately maintain the seals at the mounting screw section on
the side of the Enclosed Switch, insert each O-ring correctly and
secure it with the lock nut.
To provide the Switch with improved sealing property, use of the SC
Connector is recommended.
When routing wires into the conduit opening, be sure that cuttings
and other foreign matter do not enter the Switch.
Side Diagonal Mounting
Two, 5.4 dia.
mounting holes or
M5 screw holes
Mounting
Mounting Holes
Side Mounting
Bottom Mounting
Two, 4.3 dia.
mounting holes or
M4 screw holes
Two, 4.3 dia.
mounting holes or
M4 screw holes
Environmental Precautions
Sealing materials may deteriorate when used outdoors or when
exposed to cutting oil, solvents, or chemicals. Check this on actual
equipment and, if deterioration is foreseen, consult your OMRON
representative in advance.
Be sure to protect part A with grease in order to maintain the
mechanical life and performance of the Limit Switch. The use of
molybdenum disulfide grease is recommended.
Operation
Operating method, shape of cam or dog, operating frequency, and
the overtravel (OT) have significant effect on the service life and
precision of the Limit Switch. Make sure that the shape of the cam
is smooth enough.
Check that OT has a sufficient margin. The actual OT should be
rated OT x 0.7 to 1.
Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten each
screw to the proper tightening torque as shown below.
No.
1
2
3
4
5
Type
Cover mounting screw
Switch mounting screw (see note 1)
Switch mounting screw (see note 2)
Switch terminal screw (M4 screws for
head)
Roller arm mounting nut
Torque
1.18 to 1.37 N·m
1.18 to 1.37 N·m
4.90 to 5.88 N·m
0.78 to 1.18 N·m
4.90 to 5.88 N·m
Dedicated Wrench
The roller arm can be set freely within a range of 225° after loosening
the nut.
The roller arm mounting bracket can be set in any direction after
loosening the nut.
Note: 1.
This torque range applies to side mounting or bottom
mounting. (M4 screws for head)
2.
This torque range applies to side diagonal mounting. (M5
Allen-head bolt)
A dedicated wrench is provided separately.
Model: SUPANA FOR ZE
Make sure that the nut is free of foreign substances when the nut is
loosened.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.