E52
Exposed-lead Models
Specifications
E52-CA10AE, E52-IC10AE
Element type
K (CA), J (IC)
Dimensions
Element
diameter
0.32 mm (single
wire)
2.8-max. outer-dia.
fully glass-wool-
covered tubing
SUS304
Caulking
3.2 dia.
White/red
stripe (+)
Class
Class 2 (0.75)
SUS304
Protective
tubing material
White (−)
80
100
M
Thermal contact Non-grounded
Color code (K: Blue, J: Yellow)
type
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. Lead wire length M: 1, 2, or 4 m
Temperature
range
0°C to 350°C: K
(CA)
0°C to 200°C: J
(IC)
3. The protective tubing is of pipe construction, which must not be bent.
4. The thermocouple cannot be mounted using a PT@ Compression Fitting.
Lead wire
0°C to 180°C
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
2
4
E52-CA10AE 1M
E52-CA10AE 2M
E52-CA10AE 4M
E52-IC10AE 1M
E52-IC10AE 2M
E52-IC10AE 4M
Exclusive Models
■ Thermocouples
Thermocouples for Molding Machines
Specifications
E52-CA2GV, E52-IC2GV
Element type
K (CA), J (IC)
Dimensions
Element
diameter
1.0 mm (single
wire)
11-dia. spring metal fitting
Closely wound spring coil
Adapter (provided)
R1
Bayonet
4.8 dia. SUS304
Class
Class 2 (0.75)
SUS304
/8
M3 screw
4.1-outer-dia. glass-wool-covered
cable with external shield
6.8 dia.
K (CA)
White/red stripe (+)
J (IC)
White/red stripe (+)
Protective
tubing material
12 dia.
White/blue stripe (−)
White stripe (−)
Thermal contact Grounded type
15
25
Brass-nickel plating
25
15
22
10
Color code
(K: Blue, J: Yellow)
Y-type crimp
terminal for M4
Temperature
range
0°C to 350°C
105
M
Lead wire length (M): 1 or 2 m
Lead wire
0°C to 180°C
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
2
E52-CA2GV 1M
E52-CA2GV 2M
E52-IC2GV 1M
E52-IC2GV 2M
21