E52  
Enclosed-terminal Models (High-temperature Use)  
E52-PR@C  
Dimensions  
Dimensions are given in millimeters, except for the length (L), which  
is provided in centimeters.  
98  
Permissible Temperature in Dry Air  
Aluminum die-cast terminal box  
SUS304  
Ceramic protective tubing (t2.0)  
D
Element wire  
R
17 dia.  
17 dia.  
0°C to 1,400°C  
90  
Bending of protective  
tubing: 6 mm max.  
Terminal box: The permissible temperature  
is 0°C to 80°C.  
21.7 dia.  
40 dia.  
Note: The terminals in the cap indicate  
polarity (+ or ).  
Cap  
57  
100  
L-150  
Use wiring terminals that fit M4 screws.  
G1/2, 15-A ground (with 11-inner-dia.  
rubber bushing built-in)  
Model Information  
Element  
type  
Terminal  
type  
Protective  
Protective tubing  
tubing  
length L  
(cm)  
diameter D (mm)  
17 dia.  
Model  
R (See  
note 1.)  
Enclosed-ter- 50  
E52-PR50C D=17 PT1  
E52-PR75C D=17 PT1  
E52-PR100C D=17 PT1  
E52-PR50C D=17 PT0  
E52-PR75C D=17 PT0  
E52-PR100C D=17 PT0  
minal Models  
75  
100  
R (See  
note 2.)  
Enclosed-ter- 50  
minal Models  
75  
100  
Standard  
Protective tubing  
material  
Permissible  
temperature in dry  
air  
Note 1:  
JIS ceramic Cat.1  
(PT1)  
Mullite, high  
alumina, etc.  
1,500°C (See note.)  
Note 2:  
JIS special ceramic  
(PT0)  
Recrystallized  
alumina, fused  
alumina, etc.  
1,700°C (See note.)  
Note: The permissible temperature given for the protective tubing is  
higher than 1,400°C, but the permissible temperature of the  
thermocouple element wire is only 1,400°C. Therefore, the  
protective tubing of the E52-PR@C can withstand high  
temperatures momentarily to the levels given in the table as  
exceptions, but the element wire will deteriorate quickly if the  
thermocouple is used regularly at temperatures that exceed the  
permissible temperature for the element wire.  
16