E52
Enclosed-terminal Models (High-temperature Use)
E52-PR@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
98
Permissible Temperature in Dry Air
Aluminum die-cast terminal box
SUS304
Ceramic protective tubing (t2.0)
D
Element wire
R
17 dia.
17 dia.
0°C to 1,400°C
90
Bending of protective
tubing: 6 mm max.
Terminal box: The permissible temperature
is 0°C to 80°C.
21.7 dia.
40 dia.
Note: The terminals in the cap indicate
polarity (+ or −).
Cap
57
100
L-150
Use wiring terminals that fit M4 screws.
G1/2, 15-A ground (with 11-inner-dia.
rubber bushing built-in)
Model Information
Element
type
Terminal
type
Protective
Protective tubing
tubing
length L
(cm)
diameter D (mm)
17 dia.
Model
R (See
note 1.)
Enclosed-ter- 50
E52-PR50C D=17 PT1
E52-PR75C D=17 PT1
E52-PR100C D=17 PT1
E52-PR50C D=17 PT0
E52-PR75C D=17 PT0
E52-PR100C D=17 PT0
minal Models
75
100
R (See
note 2.)
Enclosed-ter- 50
minal Models
75
100
Standard
Protective tubing
material
Permissible
temperature in dry
air
Note 1:
JIS ceramic Cat.1
(PT1)
Mullite, high
alumina, etc.
1,500°C (See note.)
Note 2:
JIS special ceramic
(PT0)
Recrystallized
alumina, fused
alumina, etc.
1,700°C (See note.)
Note: The permissible temperature given for the protective tubing is
higher than 1,400°C, but the permissible temperature of the
thermocouple element wire is only 1,400°C. Therefore, the
protective tubing of the E52-PR@C can withstand high
temperatures momentarily to the levels given in the table as
exceptions, but the element wire will deteriorate quickly if the
thermocouple is used regularly at temperatures that exceed the
permissible temperature for the element wire.
16