 浏览型号E3F2-R4B4F-M1-M的Datasheet PDF文件第16页浏览型号E3F2-R4B4F-M1-M的Datasheet PDF文件第17页浏览型号E3F2-R4B4F-M1-M的Datasheet PDF文件第18页浏览型号E3F2-R4B4F-M1-M的Datasheet PDF文件第19页浏览型号E3F2-R4B4F-M1-M的Datasheet PDF文件第20页浏览型号E3F2-R4B4F-M1-M的Datasheet PDF文件第21页浏览型号E3F2-R4B4F-M1-M的Datasheet PDF文件第23页浏览型号E3F2-R4B4F-M1-M的Datasheet PDF文件第24页  
Precautions  
The E3F2 Photoelectric Sensor is not a safety component for ensur-  
ing the safety of people which is defined in EC directive (91/368/  
EEC) and covered by separate European standards or by any other  
regulations or standards.  
When using the photoelectric sensor in the vicinity of an inverter  
motor, ensure to connect the protective earth ground wire of the  
motor to earth. Failure to ground the motor may result in malfunction  
of the sensor.  
When you use the photoelectric sensor at temperatures exceeding  
45°C, the load current must be within the described values as shown  
in the figure below.  
Degree of protection  
The E3F2 photoelectric sensors have a degree of protection rated  
with IP67. In this case, the sensors have passed the OMRON heat  
shock test before the IP67-test of IEC 60529 (submersion at 1m  
water depth for 30 min). Afterwards the sensors have been tested  
according to the OMRON waterproof test.  
200  
130  
Heat shock: The Alternating, fast temperature changes between  
-25°C and +55°C are executed for 5 cycles and 1 hour  
for each temperature. Function and isolation are  
checked.  
Water proof: The sensors are submerged alternating in water of  
+2°C and +55°C. 20 cycles with 1 hour for each tem-  
perature are executed. Function, water tightness and  
electrical isolation are checked.  
0
45  
55  
Operating temperature (˚C)  
Do not expose the photoelectric sensor to excessive shock during  
installation, keeping within IP 67 standards.  
Installation  
Do not exceed a torque of  
Wiring  
If the input/output lines of the photoelectric sensor are placed in the  
same conduit or duct as power lines or high-voltage lines, the photo-  
electric sensor could be induced to malfunction, or even be damaged  
by electrical noise. Separate the wiring, or use shielded lines as  
input/output lines to the photoelectric sensor.  
2.0 Nm (20 kgf cm) when tightening mounting nuts for plastic  
models  
20.0 Nm (200 kgf cm) when tightening mounting nuts for metal  
models  
Do not connect the black wire to the brown wire without a load. Direct  
connection of these wires may damage the photoelectric sensor (AC  
switching type).  
Brown  
Load  
Sensor  
24 to 240 VAC  
Black  
Blue  
22  