E2E2
Pre-wired Models
E2E2-X3D@
E2E2-X2@@
E2E2-X8MD@
E2E2-X5M@@
60
55
9
60
55
9
21 dia.
17
21 dia.
7
4
10
17
4
10
9 dia.
Indicator (See note.)
Indicator (See note.)
Two
clamping nuts
Toothed washer
M12 × 1
M12 × 1
Two clamping nuts
Toothed washer
4-dia. vinyl-insulated round cable with
4-dia. vinyl-insulated round cable with 2
conductors (D, Y Models)/3 conductors
(B, C Models) (Conductor cross section:
0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
2 conductors (D, Y Models)/3 conductors
(B, C Models) (Conductor cross section:
0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
Note: D Models: Operation indicator (red),
setting indicator (green)
Note: D Models: Operation indicator (red),
setting indicator (green)
B, C, Y Model: Operation indicator (red)
B, C, Y Model: Operation indicator (red)
The cable can be extended up to 200 m
(separate metal conduit).
E2E2-X7D@
E2E2-X5@@
E2E2-X14MD@
E2E2-X10M@@
65
60
12
65
12
29 dia.
24
29 dia.
60
24
4
10
4
10
10
14.8 dia.
Indicator (See note.)
Two clamping nuts
Indicator (See note.)
Two clamping nuts
6-dia. vinyl-insulated round cable with
M18 × 1
M18 × 1
Toothed washer
Toothed washer
2 conductors (D, Y Models)/3 conductors
(B, C Models) (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
6-dia. vinyl-insulated round cable with
2 conductors (D, Y Models)/3 conductors
(B, C Models) (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
Note: D Models: Operation indicator (red),
setting indicator (green)
Note: D Models: Operation indicator (red),
setting indicator (green)
B, C, Y Model: Operation indicator (red)
B, C, Y Model: Operation indicator (red)
The cable can be extended up to 200 m
(separate metal conduit).
E2E2-X10D@@
E2E2-X10@@
70
12
42 dia.
36
65
5
10
Indicator (See note.)
Two clamping nuts
Toothed washer
M30 × 1.5
6-dia. vinyl-insulated round cable with
2 conductors (D, Y Models)/3 conductors
(B, C Models) (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
Note: D Models: Operation indicator (red),
setting indicator (green)
B, C, Y Model: Operation indicator (red)
E2E2-X20MD@
E2E2-X18M@@
70
65
12
42 dia.
36
13
5
10
26.8 dia.
Indicator
(See note.)
M30 × 1.5
Two clamping nuts
Toothed washer
6-dia. vinyl-insulated round cable with
2 conductors (D, Y Models)/3 conductors
(B, C Models) (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
Note: D Models: Operation indicator (red),
setting indicator (green)
The cable can be extended up to 200 m
(separate metal conduit).
B, C, Y Model: Operation indicator (red)
E2E/E2E2 Cylindrical Proximity Sensor
45