内容描述: [Pushbutton Switch, SPDT, Momentary, 3A, 30VDC, Solder Terminal, Panel Mount]
分类和应用: 开关光电二极管
文件页数/大小: 28 页 / 3329 K
品牌: OMRON [ OMRON ELECTRONICS LLC ]
 浏览型号A165L-AGM-24-1的Datasheet PDF文件第20页浏览型号A165L-AGM-24-1的Datasheet PDF文件第21页浏览型号A165L-AGM-24-1的Datasheet PDF文件第22页浏览型号A165L-AGM-24-1的Datasheet PDF文件第23页浏览型号A165L-AGM-24-1的Datasheet PDF文件第24页浏览型号A165L-AGM-24-1的Datasheet PDF文件第26页浏览型号A165L-AGM-24-1的Datasheet PDF文件第27页浏览型号A165L-AGM-24-1的Datasheet PDF文件第28页  
A16  
Rubber is used inside IP65 models. Do not allow the rubber to  
become scratched or foreign matter to become attached to the  
rubber.  
Scratches and foreign matter will degrade the waterproofing, and  
the Switch may fail operate correctly.  
Precautions  
1. The mounting panel thickness must be 0.5 to 3.2 mm.  
2. The mounting ring must be tightened to a torque 0.29 to 0.49 N·m.  
3. The procedure for making the mounting hole for the screw-less  
clamp connector is described on page 21. A mounting dimension  
of at least 33 mm is required, however, because the Switch is  
removed with the screw-less clamp connector mounted to the  
panel. If Switches are mounted side-by-side separated by less  
than the specified distance, it may not be possible to remove the  
Switch.  
4. Be sure to mount the Case to the Switch with the correct  
orientation. Mount with the dimple on the Case facing in the same  
direction as the side of the Switch with the direction arrow or the  
word TOP.  
Do not allow the Switch  
to drop and hit the  
ground.  
Direction arrow  
dimple  
Case  
Switch  
TOP mark  
Do not place or drop  
heavy objects on the  
Switch.  
dimple  
Case  
Switch  
Do not operate the Switch  
with hard or sharp objects.  
5. Bend the end of the wire if braided wire is used with the screw-  
less clamp connector.  
6. When wiring, insert the wire until it comes into contact with  
something. After wiring is completed, pull on the wires to confirm  
that they are connected securely.  
7. After wiring, ensure that continuous pressure is not applied to the  
terminals.  
Hammer  
Screwdriver  
Screw-less Clamp Wiring Procedure  
8. Refer to internal connection diagrams and confirm the terminal  
numbers before wiring.  
Connecting Wires  
1. Strip the wires for 10 mm (allowable range: 10± 1 mm).  
2. If braided wire is used, twist the wire to straighten it out.  
3. Insert the wire into the insertion hole while pressing the release  
button at the side of the hole. (Using a precision screwdriver is  
recommended.)  
4. Let go of the release button to lock the wire into place.  
5. After locking, pull on the wire gently to confirm that it is securely  
locked.  
Removing Wires  
1. Remove wires by pulling them while pressing the release button.  
Note: When reusing wires that have already been locked one, cut off the end of  
the wire and strip the wire again before using.  