A16□-P
Specifications
●
UL, cUL (File No. E41515)
Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.)
■Approved
Standard Ratings
5 A at 125 VAC, 3 A at 250 VAC (general use)
3 A at 30 VDC (resistive)
Note: Certification has been obtained for the
Socket Unit.
■Characteristics
Type
Item
Allowable
Mechanical
operating
frequency Electrical
Insulation resistance
Between
terminals of
same polarity
Between
terminals of
different
Dielectric
polarity
strength
Between each
terminal and
ground
Between lamp
terminals
Vibration
Malfunction
resistance
Destruction
Shock
resistance Malfunction
Durability
Mechanical
Pushbutton Switch
Momentary operation: 120 operations/minute max.
Alternate operation: 60 operations/minute max. *1
20 operations/minute max. *1
100 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute
A
1
6
@
■Ratings
P
●
Contacts
●
TÜV (EN60947-5-1)
(Low Voltage Directive)
3 A at 250 VAC
3 A at 30 VDC
●
CCC (GB14048.5)
5 A at 125 VAC
3 A at 250 VAC
3 A at 30 VDC
2,000 VAC, 50/60 Hz for 1 minute
2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute *2
10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
500 m/s
2
150 m/s
2
max. (malfunction within 1 ms)
Momentary operation: 2,000,000 operations min.
Alternate operation: 200,000 operations min. *1
100,000 operations min. *1
Class II
175
3 (IEC947-5-1)
Approx. 12 g (in the case of a lighted DPDT switch with solder terminals)
–10°C to +55°C (with no icing or condensation)
35% to 85%RH
–25°C to +65°C (with no icing or condensation)
-
Rated voltage
125 VAC
250 VAC
30 VDC
Resistive load
5
3
3
Minimum applicable load: 1 mA at 5 VDC
Rated values are obtained from tests conducted
under the following conditions.
1. Load: Resistive load
2. Mounting conditions: No vibration and no shock
3. Temperature: 20 ±2°C
4. Operating frequency: 20 operations/min
Electrical
Electric shock protection
class
PTI (tracking characteristic)
Degree of contamination
Weight
Ambient operating
temperature
Ambient operating humidity
Ambient storage
temperature
*1.
*2.
●
Contact Form
Name
Contact
NC
COM
NO
Set and reset constitute one operation.
With LED and incandescent lamp not mounted.
Double-throw
Dimensions
Rectangular A16@-J@-@P
PCB terminals
9.5
6
28.3
26.4
23.1
21.1
10.8
4
2.5
18.4 20.4
6.3
0.5
Lock ring
Mounting nut
(Unit: mm)
18
15.1
0.5
21
24
4.85 12.4 18.6
Packing (t0.5)
(for oil-resistant IP65 only)
The Dimension shows 1-switch output.
The lamp terminal is also provided with non-lighted models.
A rectangular model is listed as an example.
Unless specified, there is a tolerance of ±0.4mm for dimensions.
2