A165E
Characteristics
Type
Item
Allowable operating Mechanical
frequency
Electrical
Insulation resistance
Between terminals of different
polarity
Between lamp terminals
Vibration resistance Malfunction
Destruction
Shock resistance
Malfunction
Mechanical
Electrical
Non-lighted
A165E-S/A165E-M
20 operations/minute max.
10 operations/minute max.
100 MΩ min. (at 500 VDC)
Between terminals of same polarity
1,000 VAC, 50/60 Hz for 1 min
Dielectric strength
2,000 VAC 50/60 Hz for 1 min
Emergency Stop Switch
Lighted
A165E-LS/A165-LM
Non-lighted,
One-piece construction
A165E-U
Between each terminal and ground
2,000 VAC 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
*1
500 m/s
2
300 m/s
2
max.
(malfunction within 1 ms)
100,000 operations min.
100,000 operations min.
IP65 Oil-resistant
*2
Class II
175
3 (EN60947-5-1)
Approx. 16 g (in case of DPST-NC Switches)
−10
to 55°C (with no icing or condensation)
35% to 85%
−25
to 65°C (with no icing or condensation)
IP65
*2
IP65 Oil-resistant
*2
150 m/s
2
max.
(malfunction within 1 ms)
---
10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
Durability
Degree of protection
Electric shock protection class
PTI (tracking characteristic)
Degree of contamination
Weight
Ambient operating temperature
Ambient operating humidity
Ambient storage temperature
*1.
LED not mounted. (Test them with the LED removed.)
*2.
Degree of protection from the front of the panel.
Operating Characteristics
Type
Item
Operating force
Releasing force
Pretravel
OF max.
RF min.
PT
14.7 N
0.1 N·m
3.5±0.5 mm
Characteristics of models
with separate construction
14.7 N
0.1 N·m
3±0.5 mm
Characteristics of models
with one-piece construction
Structure and Nomenclature
Operation Unit
Color
Operation Unit Color
• Models with LED illumination: Red
• Non-lighted models
*
: Red, yellow, or gray
Operation Unit
Degree of Protection
IP65 oil resistance
Switch
Switch
Holder
Specifications
For standard load
125 VAC, 5 A
250 VAC, 3 A
30 VDC, 3 A
(The above figure is example of the
separate construction model.)
*
Models with yellow or gray pushbutton colors cannot be used as emergency switches.
4