Floatless Level Switch (Ultra High-sensitivity Type)
61F-UHS/-HSL
CSM_61F-UHS_-HSL_DS_E_2_3
Ideal for Detecting Ice, Pure Water, or
Humidity
• Applicable for detecting ice, pure water steam, humidity, or other
substances that conduct electricity poorly.
• Two types of model available: Ultra high-sensitivity and variable
ultra high-sensitivity.
Refer to
Safety Precautions for Floatless Level
Controllers.
Ordering Information
Type
Ultra high-sensitivity
Model
Ultra high-
sensitivity
61F-UHS
61F-HSL
Variable ultra high-
sensitivity
Model
Note:
When ordering, specify the desired operating voltage at the end of the model number.
Example: 61F-UHS [220VAC]
Desired supply
voltage
Ultra High-sensitivity Models
Use these models for sensing objects such as ice, high-purity distilled water, moisture, or other objects with low electrical conductivity.
Specifications
Item
Supply voltage
Operating voltage range
Interelectrode voltage
Interelectrode current
Power consumption
Interelectrode operate resistance
Interelectrode release resistance
Cable length
Control output
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Life expectancy
Weight
High-sensitivity 61F-UHS
100, 200, or 220 VAC; 50/60 Hz
85% to 110% of rated voltage
24 VAC
Approx. 1 mA AC max.
3.2 VA max.
0 to approx. 1 MΩ (see note 1)
Approx. 5 M to
∞ Ω
5 m (see note 2)
0.3 A, 220 VAC (Inductive load: cosφ = 0.4)
1 A, 220 VAC (Resistive load)
Operating:–10 to 55°C
Operating:45% to 85% RH
100 MΩ max. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min
Electrical:
50,000 operations min.
Mechanical: 5,000,000 operations min.
Approx. 210 g
Electrical:
500,000 operations min.
Mechanical: 5,000,000 operations min.
0 to approx. 5 MΩ (variable)
Operate resistance + 2.5 MΩ max.
(see note 3)
2 A, 220 VAC (Inductive load: cosφ = 0.4)
5 A, 220 VAC (Resistive load)
13 VDC max.
Approx. 1 mA DC max.
Variable high-sensitivity 61F-HSL
24, 100, 110, 200, or 220 VAC; 50/60 Hz
Note: 1.
Use 61F-UHS for detecting water leakage with high specific resistance. Connect a sensor cable between terminals 1 and 7.
2.
Two Electrodes can be connected to the 61F-HSL. Use them for an alarm, not for creating a self-holding circuit.
3.
The length when using completely-insulated, 600-V, 3-conductor (0.75 mm
2
) cabtire cables. Usable cable lengths will become shorter as
the cable diameter or number of conductors becomes larger. For more details, refer to
Safety Precautions for Floatless Level Controllers.
4.
It is recommended that the cable length be kept as short as possible since the Electrode circuit current is at DC micro-current level. More-
over, the Electrodes will corrode rapidly if the current is allowed to constantly flow between the Electrodes.
Be careful with the electrode polarity and grounding when wiring.
1