欢迎访问ic37.com |
会员登录 免费注册
发布采购

A165E-SGR-01 参数 Datasheet PDF下载

A165E-SGR-01图片预览
型号: A165E-SGR-01
PDF下载: 下载PDF文件 查看货源
内容描述: [Pushbutton Switch, SPST, Momentary, 3A, 30VDC, Solder Terminal, Panel Mount-threaded]
分类和应用: 开关
文件页数/大小: 7 页 / 846 K
品牌: OMRON [ OMRON ELECTRONICS LLC ]
 浏览型号A165E-SGR-01的Datasheet PDF文件第1页浏览型号A165E-SGR-01的Datasheet PDF文件第2页浏览型号A165E-SGR-01的Datasheet PDF文件第3页浏览型号A165E-SGR-01的Datasheet PDF文件第4页浏览型号A165E-SGR-01的Datasheet PDF文件第5页浏览型号A165E-SGR-01的Datasheet PDF文件第7页  
61F-UHS/-HSL
BS-1T
Terminal
bolt
SUS304
SUS316
Titanium
Hastelloy B
Hastelloy C
Mounting Holes
M4 nut
Width between
SUS304 flats: 20.5
Two, M4**
Hastelloy
titanium
24 dia. M18 P=1.5
(fine screw thread)
*This nut is made of Fluorine Resin
**A connecting nut made of Hastelloy B, Hastelloy
C, or titanium is not supplied
with
two M4 screws
and thus has no holes for such screws.
Material
Weight
SUS304
Approx. 55 g
SUS316
Approx. 55 g
Titanium
Approx. 45 g
HAS B
Approx. 65 g
HAS C
Approx. 60 g
PH-1
(Approx. 140 g
with
a 1-m cord)
PH-2
(Approx. 235 g
with
a 1-m cord)
Two, 6-dia. holes
Resin
26 dia. 27 dia. 5 dia.
PVC resin (black)
19 dia.
Single-core
cable
Two-core
cable
Cable OD:
Vinyl
5.0 dia., Hypalon 6.5 dia.
Note:
Cable is supplied in lengths of 1, 5, 10, 15, 20, 30, 40,
50, 60, 70,
80,
90, or 100 meters.
Cable OD:
Vinyl,
Hypalon 6.8 dia.
Electrode Separators
F03-14 1P for one pole
6.5 dia.
F03-14 3P for three poles
Three, 7 dia.
F03-14 5P for five poles
Five, 7 dia.
20
28 dia.
Weight:
Approx. 15 g
20
41
Weight:
Approx. 30 g
46
Weight:
Approx. 30 g
Safety Precautions
Refer to
Safety Precautions for All Level Controllers.
Precautions for Correct Use
Short Wiring in Electrode Circuit
Keep the wires connecting the Controller to Electrode Holders as
short as possible. If long leads are used, the floating capacity of the
leads, and abnormal surges or noise in the Electrode circuit can
cause malfunctions.
The thicker the cables, the shorter the permitted wiring length. The
length of the cable connecting the Controller and Electrode is
specified in the Controller datasheet as a guideline assuming that a
600-V VCT 0.75-mm
2
, 3-core cabtire cable is used. Test results
indicate that the actual wiring length using VCT 3.5-mm
2
, 3-core
cable laid over the ground is 50% of the specified length for
general-purpose applications and 80% of the specified length for
long-distance applications. When selecting cable specifications,
remember that the wiring length is further decreased for
underground cables and larger diameter cables because of the
increased floating capacity with the ground.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
6