I
Accessories (Order Separately)
Selection Guide for Electrode Holders and Separators
Electrode Holders
Applications
For city water and other
general-use electrodes.
Easy-to-replace sepa-
rate versions facilitate
maintenance of elec-
trodes.
Flange
Phenol resin
70°C
When mounting space is
limited. Special 3-pole
holder of small size and
light weight. Ideal for soft
drink vendors, etc., where
only limited space is avail-
able.
Screw
Phenol resin
For low specific liquids. Used for sewage,
sea water, etc., having a low specific resis-
tance. In sewage use, electrode holders
must be installed 10 to 20 cm apart from
one another. For acids, alkalis and sea wa-
ter, electrode holders may be as much as
1 meter apart to operate properly.
Flange
Ceramics
When resistance to high
pressure is required. Ide-
al for use in tanks where
temperature or pressure
inside the tank is high,
e.g. 250°C
Screw
Teflon
Mounting style
Insulator material
Max. temperature
150°C (without water drips or vapor on the 250°C (without water
surface of the electrode holder)
drips or vapor on the sur-
face of the electrode
holder)
---
PS-31
BF-1
---
BS-1
---
No. of
electrodes
1
3
---
PS-3S
Electrode Separators
No. of electrodes
1
3
Model
F03-14 1P
F03-14 3P
Selection Guide for Electrodes, Connecting, and Lock Nuts
Applicable liquids
Material
Model
Purified city water,
industrial water,
sewage
Purified city water,
industrial water,
sewage, dilute
alkaline solution
Equivalent
to SUS 304
(AISI-304)
SUS316
(AISI-316)
F03-01 SUS201
Models for individual electrode assembly components
Electrode (1m long)
Indication
mark
1 line
Connecting nut
Model
F03-02 SUS201
Inscription
---
Lock nut
Model
F03-03 SUS201
Inscription
---
F03-01 SUS316
2 lines
F03-02 SUS316
6
F03-03 SUS316
316
E-6
Conductive Level Controller
61F-GP-N8