Alternate Operation Relay
61F-AN/-APN2
CSM_61F-AN_-APN2_DS_E_3_1
Increases Motor Life and Enables Operating
Only One Pump When Cleaning Tanks or as
an Emergency Measure for Pump Failures.
• Electronic Relay with the same operation as the G4Q Latching
Relay. Compared with the G4Q, the 61F-AN/-APN2 has a
shorter power supply application time and no restrictions on
mounting direction.
• Compact Models (61F-AN) and Compact Plug-in Models (61F-
APN2) available.
Note:
A changeover switch must be included in the sequence to enable
operating only one pump.
Refer to
Safety Precautions for Floatless Level
Controllers.
■
Ordering Information
Type
Alternate Operation 61F-AN
Relay
61F-APN2
Note:
When ordering, specify the desired operating voltage at the end of the model number.
Example: 61F-AN [220VAC]
Model
Desired supply
voltage
■
Specifications
Ratings
Supply voltage
Operating voltage range
Power consumption
Accessories
100, 110, 200, 220 VAC; 50/60 Hz
85% to 110% of rated voltage
3 VA
Hold-down clip PFC-N8 *
* Hold-down clip PFC-N8 is attached only 61F-APN2.
Contact Ratings (with G2RK Keep Relay)
Item
Max. load
Carry contact
Max. operating current
Max. switching capacity
3A
3A
750 VA
375 VA
Resistive load (cosφ = 1)
3 A at 250 VAC
Inductive load (cosφ = 0.4, L/R = 7 ms)
1.5 A at 250 VAC
Characteristics
Response time
Minimum pulse width
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Operate: 25 ms max.
Release: 30 ms max.
Min. ON time: 40 ms min.
Min. OFF time: 200 ms min.
100 MΩ min. at 500 VDC (between each terminal and power supply)
2,000 VAC, 50/60 Hz for 1 min (between each terminal and power supply)
10 to 55 Hz, 1-mm double amplitude
10 G (approx. 98 m/s
2
)
Mechanical: 1,000,000 operations (at operating frequency of 1,800 operations/hour)
Electrical: 100,000 operations min.
(rated load)
Operating: –10 to 55°C
Operating: 45% to 85% RH
61F-AN: Approx. 215 g
61F-APN2: Approx. 190 g
Ambient temperature
Ambient humidity
Weight
1