mc-S Series
Safety interlock Switches
Applications
Typical applications are on sliding guard
doors or swinging guard doors.
MC-S
Actuator
MC-S
Sensor
Red
Green
Yellow
Blue
1 2 3 4
MC-SS2
Actuator
MC-S
Control Unit
MC-SS2
Sensor
Green
Red
Gray
Yellow
Blue
1 2 3 4
Black
White
Auxiliary Contacts
for Indication - N/C or N/O
Black
White
MC-S
Control Unit
Auxiliary Contacts
for Indication - N/C or N/O
24 VAC/DC
Blue
MC-S Series
Actuator
MC-S Series
Sensor
Guard
Closed
Yellow
Green
2 1 A1 +
33 23 21
Yellow
STOP
START
K1 (Aux)
K2 (Aux)
Momentary
Push Button
Momentary
Push Button
L1
L2 L3
g
MC-S2 Series
Control
Unit
3 4 A2 - X1 X2
Green
Red
K2 (Aux)
32 14 24
K1 (Aux)
Fuse
Fuse
K1
K2
CONTACT
PROTECTION
E.G. Thermal
Cut Out
K2
RESET
Momentary
Push Button
K1
M
Single sensor and two contactors with manual reset and EDM (External Device Monitoring). Machine will start when
guard is closed, auxiliary contacts at K1 and K2 are closed (i.e. both contactors are off), reset button is pressed and
then start button is pressed.
24 VAC/DC
MC-S Series
Actuator 1
MC-S Series
Sensor 1
Yellow
Green
Blue
Yellow
STOP
START
K1 (Aux)
K2 (Aux)
Guard
Closed
Momentary
Push Button
Momentary
Push Button
Red
L1
2 1 A1 +
31 13 23
L2 L3
L1
L2 L3
Blue
MC-S Series
Actuator 2
MC-S Series
Sensor 2
Guard
Closed
Yellow
Green
MC-S2 Series
Control
Unit
3 4 A2 - X1 X2
32 14 24
K1 (Aux)
Fuse
Fuse
K1
CONTACT
PROTECTION
E.G. Thermal
Cut Out
K2
K2
Blue
Red
MC-S Series
Actuator 3
MC-S Series
Sensor 3
Guard
Closed
Yellow
Green
Green
Red
K2 (Aux)
Momentary
Push Button
RESET
K1
M
M
Three sensors and two contactors with manual reset and EDM (External Device Monitoring). Machine will start
when all guards are closed, reset button is pressed and then start button is pressed. NOTE: The use of multiple
sensors connected to a single control unit is only suitable in applications where each guard door is always
opened and then shut individually. Otherwise some single faults may not be detected and unintentional lockout
reset may occur if two or more guard doors are open at the same time.