Rack Components  
Section 2-3  
CV500-PS221/CVM1-PA208  
POWER Indicator  
Lights when power  
is supplied.  
Connect a 100 to 120-VAC or 200 to  
240-VAC power source.  
AC input  
Short the  
(LG) terminal to the  
(GR)  
terminal to improve noise immunity and  
prevent electric shock.  
Ground this terminal at a resistance of  
less than 100 W to prevent electric shock.  
Use an independent ground not shared  
with other equipment.  
NC  
NC  
These terminals are short-circuit at  
the factory. Remove the sort-circuit  
bracket to allow enabling and disab  
ling of the PC with an external signal  
(input: 24 VDC,10 mA). Normally  
leave them short-circuited. These ter  
minals are used on CPU Racks only.  
-
START input  
RUN output  
,
-
These terminals are turned ON during RUN  
operation.  
Maximum Switching Capacity:  
250 VAC: 2 A (resistive load, cosf = 1)  
250 VAC: 0.5 A (inductive load, cos  
24 VDC: 2 A  
f = 0.4)  
Terminals for external  
connections  
CV500-PS211  
POWER Indicator  
Lights when power  
is supplied.  
Note When complying with EC Directives (low voltage), use rein-  
forced insulation or double insulation on the DC power supply  
.
DC input  
Connect a 24-VDC power source.  
Short the  
(LG) terminal to the  
(GR)  
terminal to improve noise immunity and  
prevent electric shock.  
Ground this terminal at a resistance of  
less than 100 W to prevent electric shock.  
Use an independent ground not shared  
with other equipment.  
NC  
NC  
These terminals are short-circuited at  
the factory. Remove the sort-circuit  
bracket to allow enabling and disab  
ling of the PC with an external signal  
(input: 24 VDC, 10 mA). Normally  
leave them short-circuited. These ter  
minals are used on CPU Racks only.  
-
START input  
RUN output  
,
-
These terminals are turned ON during RUN  
operation.  
Maximum Switching Capacity:  
250 VAC: 2 A (resistive load, cosf = 1)  
250 VAC: 0.5 A (inductive load, cos  
24 VDC: 2 A  
f = 0.4)  
Maximum Switching Capacity when Meeting  
EC Directives (Low-voltage Directives):  
24 VDC: 2 A  
T
erminals for external  
connections  
35  