Specifications
Appendix B
Triac Output Units Continued
Item
C500-OA226
Max. Switching Capacity
Max. Inrush Current
1.2 A, 250 VAC, 50/60 Hz (4 A/common, 5 A/Unit)
15 A (pulse width: 100 ms)
30 A (pulse width: 10 ms)
Min. Switching Capacity
100 mA, 10 VAC
50 mA, 24 VAC
10 mA, 100 VAC
10 mA, 240 VAC
Leakage Current
Residual Voltage
1.5 mA (120 VAC, 60 Hz) max.
3.0 mA (240 VAC, 60 Hz) max.
1.5 VAC (100 to 600 mA) max.
1.5 VAC (50 to 100 mA) max.
5.0 VAC (10 to 50 mA) max.
ON Delay
1 ms max.
OFF Delay
1/2 of load frequency + 1 ms max.
16 (8 outputs/common, 2 circuits)
450 mA, 5 VDC max.
No. of Outputs
Internal Current Consumption
Fuse Capacity
Weight
5 A, 250 V, 6.35 dia. x 32 (2 fuses)
600 grams max.
Circuit Configuration
OUT 00
f
Ω
f Ω
to
0.022
F
OUT 06
OUT 07
Fuse/
fuse blowout
detection circuit
COM
OUT 08
to
f
Ω
f
Ω
0.022
F
OUT 14
OUT 15
Fuse/
fuse blowout
detection circuit
COM
The fuse is 5 A, 250 V and 6.35 mm dia. x 32 mm.
0
Terminal Connections
L
L
L
L
L
L
L
L
0
1
2
3
4
5
6
7
8
1
2
3
4
250 VAC max.
~
5
6
7
COM
8
L
L
L
L
L
L
L
L
9
9
10
11
12
13
14
15
16
17
18
19
10
11
12
13
14
15
COM
250 VAC max.
~
NC
NC
Dimensions
C-shape
125