Motion Control and
Drive Technology
Specifications
230 V class
Single−phase: 3G3MV−_
Three−phase: 3G3MV−_
Maximum permissible motor output
Output data
p
Inverter rating
Rated output current
Max. output voltage
Output frequencies
Supply
Rated input voltage
and frequency
Max. voltage deviation
Max. frequency deviation
Weight
kg
kW
kVA
A
AB001
A2001
0.12
0.3
0.8
AB002
A2002
0.25
0.6
1.6
Frequency Inverter 3G3MV
AB004
A2004
0.55
1.1
3.0
AB007
A2007
1.1
1.9
5.0
AB015
A2015
1.5
3.0
8.0
AB022
A2022
2.2
4.2
11.0
AB040
A2040
4.0
6.7
17.5
Proportional to input voltage: 0..240 V
0.1..400 Hz
200..240 VAC, 50/60 Hz
−15%..+10%
+5%
0.5
0.5
0.5
0.8
0.8
1.3
1.5
400 V class
Three−phase: 3G3MV−_
Maximum permissible motor output
Output data
p
Inverter rating
Rated output current
Max. output voltage
Output frequencies
Supply
Rated input voltage
and frequency
Max. voltage deviation
Max. frequency deviation
Weight
kg
kW
kVA
A
A4002
0.25
0.9
1.2
A4004
0.55
1.4
1.8
A4007
1.1
2.6
3.4
A4015
1.5
3.7
4.8
A4022
2.2
4.2
5.5
A4030
3.0
5.5
7.2
A4040
4.0
7.0
9.2
A4055
5.5
11.0
14.8
A4075
7.5
13.8
18.0
Proportional to input voltage: 0..400 V
0.1..400 Hz
380..460 VAC, 50/60 Hz
−15%..+10%
+5%
1.3
1.3
1.3
1.3
1.5
2.0
2.0
2.0
2.0
418