Operation  
Chapter 5  
H Data Display and Action to be Taken when Warning Status  
Arises  
The ALARM indicator flashes when warning status arises. The data display section also  
flashes.  
When warning status arises, no error code is output.  
Eliminating the cause recovers the system automatically.  
Data  
Description  
Action  
display  
ef  
Simultaneous input of forward and Review the sequence.  
reverse rotation commands  
flashing  
Forward and reverse rotation  
commands were simultaneously input  
for 0.5 second or more. The Inverter  
decelerates and stops the motor.  
Main circuit undervoltage (UV)  
Check the power voltage.  
uU  
flashing  
The DC voltage of the main circuit  
dropped below the low-voltage  
detection level when the Inverter was  
stopped.  
Check the power input line for discon-  
nection.  
Check the terminal block screws for  
looseness.  
Main circuit overvoltage (OV)  
Check the power voltage.  
%U  
flashing  
The DC voltage of the main circuit  
exceeded the overvoltage detection  
level when the Inverter was stopped.  
Radiation fin overheated (OH)  
Check the ambient temperature.  
%h  
flashing  
The radiation fin overheated when the  
Inverter was stopped.  
Install a cooling fan or air conditioner.  
Digital Operator stopped (STP)  
Open both SF and SR.  
flashing  
The STOP/RESET Key on the Digital  
Operator was pressed while the  
Inverter was being operated using  
control circuit terminals SF and SR.  
The Inverter decelerates and stops  
the motor.  
5-3  