Specifications
Chapter 6
---
A4002(-j) A4004(-j) A4007(-j) A4015(-j)
Model 3G3EV-
Three
phase,
400 VAC
Power
supply
Rated voltage
and frequency
Three-phase, 380 to 460 VAC, 50/60 Hz
Allowable
voltage
–15% to 10 %
fluctuation
Allowable
frequency
fluctuation
±5%
Heating value (W)
Weight (kg)
---
---
25.5
1.0
34.7
1.0
56.0
1.5
78.5
2.0
Maximum applicable motor capacity ---
0.2 (0.37) 0.4 (0.55) 0.75 (1.1) 1.5 (1.5)
(kW)
Output
specifi-
cations
Rated output capacity
(kVA)
Rated output current (A)
Rated output voltage
---
---
0.9
1.2
1.4
1.8
2.6
3.4
3.7
4.8
Three-phase, 380 to 460 VAC
(Corresponds to the input voltage)
Maximum output
frequency
400 Hz (Parameter setting)
Cooling method
Self-cooling
H General Specifications
Installation type
Installation site
Panel mounting
Indoor (free from corrosive gases and dust)
Ambient temperature for
operation
–10° to 50°C
Humidity
90% or less (no-condensing)
Ambient temperature for storage –20° to 60°C
Altitude
1,000 m max.
Less than 20 Hz: 1G {9.8 m/s2} or less
20 to 50 Hz:
Vibration resistance
0.2G {1.96 m/s2} or less
Cable length between Inverter
and motor
100 m max.
6-3