D Setting Constants Using the PRGM Indicator
Example:
Changing the value of constant no. 02 (operation mode selection) to “2.”
Key
operation
Indicator Example of
data display
Explanation
Press the Mode Key until the PRGM indicator
lights up.
n01
n02
Press the Increment Key. “n02” appears in the
data display section.
Press the Enter Key. The value of constant no. 02
is displayed.
0
Flashing
2
Change the value to “2” by pressing the Increment
Key. The data display section flashes (indicating
that the value is yet to be registered).
Press the Enter Key. The data display section
stops flashing.
2
After approximately 0.5 second, the data display
section returns to the constant no. display (“n02”).
n02
Flashing
n01
n02
0
2
2
n02
(After 0.5
second)
Note 1. If the new data is not to be registered, press the Mode Key instead of the Enter
Key. The new data becomes invalid and the constant no. display (“n02”) is re-
turned.
Note 2. Holding down the Increment Key or Decrement Key changes data quickly.
4-9