 浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第36页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第37页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第38页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第39页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第41页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第42页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第43页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第44页  
Specifications  
Chapter 4  
4-1 Specifications of Main Unit  
H Ratings  
Model 3G3EV-  
A2001(M)- A2002(M)- A2004(M)- A2007(M)- A2015(M)-  
CUE CUE CUE CUE CUE  
Three  
phase,  
200 VAC  
Power  
supply  
Rated voltage and Three-phase, 200 to 230 VAC, 50/60 Hz  
frequency  
Allowable voltage –15% to 10 %  
fluctuation  
Allowable  
frequency  
fluctuation  
5%  
Heating value (W)  
Weight (kg)  
11.9  
0.5  
18.8  
0.6  
33.2  
0.9  
51.7  
71.6  
1.3  
1.5  
1.5  
Maximum applicable motor capacity  
(kW)  
0.1  
0.2  
0.4  
0.75  
Output  
specifi-  
cations  
Rated output capacity (kVA) 0.3  
0.6  
1.5  
1.1  
3.0  
1.9  
5.0  
2.7  
7.0  
Rated output current (A)  
Rated output voltage  
0.8  
Three-phase, 200 to 230 VAC (Corresponds to the input  
voltage)  
Maximum output frequency  
400 Hz (Parameter setting)  
Self-cooling  
Cooling method  
Model 3G3EV-  
AB001(M)- AB002(M)- AB004(M)- AB007(M)- AB015(M)  
CUE  
CUE  
CUE  
CUE  
-CUE  
Single  
phase/  
Three  
phase,  
200 VAC  
Power  
supply  
Rated voltage and Single-phase/Three-phase, 200 to 240 VAC, 50/60 Hz  
frequency  
Allowable voltage –15% to 10 %  
fluctuation  
Allowable  
frequency  
fluctuation  
5%  
Heating value (W)  
Weight (kg)  
Maximum applicable motor capacity  
(kW)  
12.6  
0.5  
20.3  
0.6  
25.3  
1.3  
55.3  
1.3  
78.4  
2.0  
1.5  
0.1  
0.2  
0.4  
0.75  
Output  
specifi-  
cations  
Rated output capacity (kVA) 0.3  
0.6  
1.5  
1.1  
3.0  
1.9  
5.0  
2.7  
7.0  
Rated output current (A)  
Rated output voltage  
0.8  
Three-phase, 200 to 230 VAC (Corresponds to the input  
voltage)  
Maximum output frequency  
400 Hz (Parameter setting)  
Self-cooling  
Cooling method  
Note Model numbers with a suffix of “-CUE” indicate models approved by UL. (Approval has not been  
obtained for models with a model number suffix of “-CE.”)  
4-2  