 浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第28页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第29页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第30页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第31页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第33页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第34页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第35页浏览型号3G3EV-AB007-CUE的Datasheet PDF文件第36页  
Design  
Chapter 3  
If the regenerative energy exceeds the Inverter capacity, overvoltage will be detected in the main circuit.  
In such a case, use a Braking Resistor or Braking Resistor Unit.  
Note Be sure to create a sequence that will turn OFF the Inverter power supply when resistor over-  
heating occurs. When using a Braking Resistor, be sure to install a thermal relay to detect resis-  
tor overheating. When using a Braking Resistor Unit, use an error output contact. Otherwise, a  
fire may occur.  
Model 3G3IV-  
Model 3G3EV-  
Minimum connected  
resistance  
Braking Resistor  
Braking Resistor Unit  
(Duty Cycle 10%ED)  
(Duty Cycle 3%ED)  
PERF150WJ401 (400 ) ---  
200 Ω  
A2001(M)-CUE  
A2002(M)-CUE  
A2004(M)-CUE  
A2007(M)-CUE  
A2015(M)-CUE  
AB001(M)-CUE  
AB002(M)-CUE  
AB004(M)-CUE  
AB007(M)-CUE  
AB015(M)-CUE  
A4002(M)-CUE  
A4004(M)-CUE  
A4007(M)-CUE  
A4015(M)-CUE  
PERF150WJ201 (200 ) PLKEB20P7 (200 70 W)  
80 Ω  
PERF150WJ101 (100 ) PLKEB21P5 (100 260 W) 60 Ω  
PERF150WJ401 (400 ) ---  
200 Ω  
PERF150WJ201 (200 ) PLKEB20P7 (200 70 W)  
80 Ω  
PERF150WJ101 (100 ) PLKEB21P5 (100 260 W) 60 Ω  
PERF150WJ751 (750 ) PLKEB40P7 (750 70 W)  
750 Ω  
510 Ω  
PERF150WJ401 (400 ) PLKEB41P5 (400 260 W) 240 Ω  
Note Do not use a Resistor whose resistance is below the minimum connected resistance. Other-  
wise, the Inverter will be damaged.  
H Wiring on the Output Side of Main Circuit  
D Connecting the Terminal Block to the Load  
Connect output terminals U, V, and W to motor lead wires U, V, and W, respectively.  
D Never Connect Power Supply to Output Terminals  
Caution  
Never connect a power supply to output terminals L1, N/L2, and L3.  
If voltage is applied to the output terminals, the internal mechanism of the Inverter  
will be damaged.  
!
D Never Short or Ground the Output Terminals  
Caution  
If the output terminals are touched with bare hands or the output wires come into  
contact with the Inverter casing, an electric shock or grounding will occur. This is ex-  
tremely hazardous. Also, be careful not to short the output wires.  
!
D Do Not Use a Phase Advance Capacitor or LC/RC Noise Filter  
Never connect a phase advance capacitor or LC/RC Noise Filter to the output circuit. Doing so may  
result in damage to the Inverter or cause other parts to burn.  