Section 1-3
1-3
Comparing the C500-LDP01 and the C500-LDP01-V1
The following table shows the improvements that have been made to create the
C500-LDP01-V1.
Item
C500-LDP01
40 instructions
C500-LDP01-V1
The following instructions were added to make a
total of 49 instructions.
ASL(25): ARITHMETIC SHIFT LEFT
ASR(26): ARITHMETIC SHIFT RIGHT
ROL(27): ROTATE LEFT
ROR(28): ROTATE RIGHT
COM(29): COMPLEMENT
INC(38): INCREMENT
DEC(39): DECREMENT
SLD(74): ONE DIGIT SHIFT LEFT
SRD(75): ONE DIGIT SHIFT RIGHT
Instruction set
Number of
2 words
words allocated 16 PC output bits (0000 through 0015)
16 PC input bits (0100 through 0115)
The PC cannot access the Unit using the I/O
WRITE and the I/O READ (WRIT(87)/READ(88))
instructions.
Operating
modes
2 words
16 PC output bits (0000 through 0015)
16 PC input bits (0100 through 0115)
With the proper switch settings, the PC can
control the Unit using the I/O WRITE and I/O
READ (WRIT(87)/READ(88)) instructions.
(Up to 32 words are written or read.)
Linked
operation
RUN
PROGRAM
Linked
operation
RUN
MONITOR
(DEBUG)
PROGRAM
Independent
operation
RUN
PROGRAM
Independent
operation
RUN
MONITOR
(DEBUG)
PROGRAM
The GPC/FIT/LSS* can operate with the Unit in
PROGRAM mode only.
The GPC/FIT/LSS* can operate with the Unit in
either PROGRAM or MONITOR (debug) mode.
*GPC: Graphic Programming Console
FIT:
Factory Intelligent Terminal
LSS: Ladder Support Software