VAQ
Specifications
Characteristics
Operating Mechanical
frequency Electrical
Insulation resistance
Contact resistance
Between terminals of
same polarity
Dielectric
strength
Between current-
carrying metal part and
ground, and between
each terminal and non-
current-carrying metal
part
120 operations/min
20 operations/min
100 MΩ min. (at 500 VDC)
30 mΩ max. (initial value)
1,000 VAC, 50/60 Hz for 1
minute
Operating characteristics
Operating force
Releasing force
Pretravel
OF max.
RF min.
PT max.
Operating Characteristics
Output
1
1.96 N
0.39 N
1.3 mm
2
4.90 N
0.78 N
1.6 mm
Contact Form
1,500 VAC, 50/60 Hz for 1
minute
Name
Contact form
Vibration
Malfunction
resistance
Destruction
Shock
resistance Malfunction
Durability
Weight
Inrush
current
NC
NO
Mechanical
Electrical
10 to 55 Hz, 1.5 mm
double amplitude
*
500 m/s
2
200 m/s
2
max.
*
3,000,000 operations min.
100,000 operations min.
Approx. 12 to 40 g
36 A max.
36 A max.
–25 to 80°C (with no icing or
condensation)
35% to 85%RH
–25 to 80°C (with no icing or
condensation)
IP00
Class II
175
3 (IEC947-5-1)
Double-throw contacts
COM
NC
NO
Approved Standard Ratings
•
The built-in V-15-1A5 Switch is approved for UL and CSA.
Ambient operating temperature
Ambient operating humidity
Ambient storage temperature
Degree of protection
Electric shock protection class
PTI (proof tracking index)
Pollution degree
* Malfunction within 1 ms
Dimensions
VAQ-4@-K
Insert one of the following letters into the box (@) in the model number. Refer to Ordering Information for color symbols.
(Unit: mm)
3
×
16 tapping screw
*4
11
18
5.6 dia. 6 dia.
Width across hexagonal nut flats: 14,
Thickness: 2.
15 dia. (lock
washer)
Face nut thickness: 2, Diameter: 14.
One, M10
13 dia.
*2
*3
*1
38
22.2
7
28
Note: The Operation Unit can be
inserted and removed.
11.4
10
8.6
10.3
3
21.9
25
FP: 24.5 max.
*1.
*2.
*3.
*4.
Unthreaded screw section: Approx. one thread
Thermoplastic resin foam
V-15-1A5
Miniature Basic Switch
Three, #187 tab/solder terminals (t = 0.5)
2