欢迎访问ic37.com |
会员登录 免费注册
发布采购

ML9206-XX 参数 Datasheet PDF下载

ML9206-XX图片预览
型号: ML9206-XX
PDF下载: 下载PDF文件 查看货源
内容描述: 5× 7点阵字符x 16位数字显示控制器/驱动器,带有字符RAM [5 x 7 Dot Character x 16-Digit Display Controller/Driver with Character RAM]
分类和应用: 驱动器显示控制器
文件页数/大小: 33 页 / 354 K
品牌: OKI [ OKI ELECTRONIC COMPONETS ]
 浏览型号ML9206-XX的Datasheet PDF文件第6页浏览型号ML9206-XX的Datasheet PDF文件第7页浏览型号ML9206-XX的Datasheet PDF文件第8页浏览型号ML9206-XX的Datasheet PDF文件第9页浏览型号ML9206-XX的Datasheet PDF文件第11页浏览型号ML9206-XX的Datasheet PDF文件第12页浏览型号ML9206-XX的Datasheet PDF文件第13页浏览型号ML9206-XX的Datasheet PDF文件第14页  
¡ Semiconductor  
ML9206-xx  
AC Characteristics-1  
(VDD=5.0V 10ꢀ, VFL=–60V, Ta=–40 to +85°C, unless otherwise specified)  
Parameter  
CP Frequency  
Symbol  
fC  
Condition  
Min.  
Max.  
2.0  
Unit  
MHz  
ns  
CP Pulse Width  
DA Setup Time  
DA Hold Time  
tCW  
250  
250  
250  
250  
16  
tDS  
ns  
tDH  
ns  
CS Setup Time  
CS Hold Time  
tCSS  
tCSH  
tCSW  
tDOFF  
ns  
R1=3.3kW, C1=47pF  
ms  
CS Wait Time  
250  
8
ns  
Data Processing Time  
R1=3.3kW, C1=47pF  
ms  
When RESET signal is input from  
RESET Pulse Width  
tWRES  
250  
250  
ns  
ns  
microcontroller etc. externally  
When RESET signal is input from  
microcontroller etc. externally  
RESET Time  
tRSON  
R2=1.0kW, C2=0.1mF  
250  
200  
ms  
ns  
DA Wait Time  
tRSOFF  
tR  
2.0  
2.0  
100  
ms  
ms  
ms  
ms  
tR=20ꢀ to 80ꢀ  
Cl=100pF  
All Output Slew Rate  
tF  
tF=80ꢀ to 20ꢀ  
V
DD Rise Time  
tPRZ  
tPOF  
When mounted in the unit  
VDD Off Time  
When mounted in the unit, VDD=0.0V  
5.0  
AC Characteristics-2  
(VDD=3.3V 10ꢀ, VFL=–60V, Ta=–40 to +85°C, unless otherwise specified)  
Parameter  
CP Frequency  
Symbol  
fC  
Condition  
Min.  
Max.  
2.0  
Unit  
MHz  
ns  
CP Pulse Width  
DA Setup Time  
DA Hold Time  
tCW  
250  
250  
250  
250  
16  
tDS  
ns  
tDH  
ns  
CS Setup Time  
CS Hold Time  
tCSS  
tCSH  
tCSW  
tDOFF  
ns  
R1=3.3kW, C1=39pF  
ms  
CS Wait Time  
250  
8
ns  
Data Processing Time  
R1=3.3kW, C1=39pF  
ms  
When RESET signal is input from  
RESET Pulse Width  
tWRES  
250  
250  
ns  
ns  
microcontroller etc. externally  
When RESET signal is input from  
microcontroller etc. externally  
RESET Time  
tRSON  
R2=1.0kW, C2=0.1mF  
250  
200  
ms  
ns  
DA Wait Time  
tRSOFF  
tR  
2.0  
2.0  
100  
ms  
ms  
ms  
ms  
tR=20ꢀ to 80ꢀ  
Cl=100pF  
All Output Slew Rate  
tF  
tF=80ꢀ to 20ꢀ  
V
DD Rise Time  
tPRZ  
tPOF  
When mounted in the unit  
VDD Off Time  
When mounted in the unit, VDD=0.0V  
5.0  
10/32