Initial Setting of Instructions  
(a) Data transfer from and to the CPU using 8 bits of DB0 to DB7  
1) Turn on the power.  
2) Wait for 15 ms or more after V has reached 2.5V or higher.  
DD  
3) Set “8 bits” with the Function Setting instruction.  
4) Wait for 4.1 ms or more.  
5) Set “8 bits” with the Function Setting instruction.  
6) Wait for 100 ms or more.  
7) Set “8 bits” with the Function Setting instruction.  
8) Check the Busy Flag for No Busy (or wait for 100 ms or more).  
9) Set “8 bits”, “Number of LCD lines” and “Font size” with the Function Setting instruction.  
(After this, the number of LCD lines and the font size cannot be changed.)  
10) Check the Busy Flag for No Busy.  
11) Execute the Display Mode Setting Instruction, Display Clear Instruction, Entry Mode  
Setting instruction and Arbitrator Display Line Setting Instruction.  
12) Check the Busy Flag for No Busy.  
13) Initialization is completed.  
An example of instruction code for 3), 5) and 7)  
RS1  
1
RS0  
0
R/W  
DB7  
0
DB6  
0
DB5  
1
DB4  
1
DB3  
DB2  
DB1  
DB0  
0
¥
¥
¥
¥
¥ : Don't Care  
(b) Data transfer from and to the CPU using 8 bits of DB4 to DB7  
1) Turn on the power.  
2) Wait for 15 ms or more after V has reached 2.5V or higher.  
DD  
3) Set “8 bits” with the Function Setting instruction.  
4) Wait for 4.1 ms or more.  
5) Set “8 bits” with the Function Setting instruction.  
6) Wait for 100 ms or more.  
7) Set “8 bits” with the Function Setting instruction.  
8) Check the Busy Flag for No Busy (or wait for 100 ms or longer).  
9) Set “4 bits” with the Function Setting instruction.  
10) Wait for 100 ms or longer.  
11) Set “4 bits”, “Number of LCD lines” and “Font size” with the Initial Setting instruction.  
(After this, the number of LCD lines and the font size cannot be changed.)  
12) Check the Busy Flag for No Busy.  
13) Execute the Display Mode Setting Instruction, Display Clear Instruction, Entry Mode  
Setting instruction and Arbitrator Display Line Setting Instruction  
14) Check the Busy Flag for No Busy.  
15) Initialization is completed.  
An example of instruction code for 3), 5) and 7)  
RS1  
1
RS0  
0
R/W  
DB7  
0
DB6  
0
DB5  
1
DB4  
1
0
46/54  