2.3.6 Luminance Continuous Code Motion Compensation Level Setting
SUB_ADDRESS = 50h(W): Luminance Continuous Code Motion Compensation Level Setting
DATA_BIT
BIT7
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
0
AYMS
YMS
Register name
A2OFF (Reserved)
1
0
3
2
1
YMS[3:0] Initial value: 0100; Setting range: 0000 to 1111
Sets luminance signal continuous code motion compensation level.
Settable in 0 to 30 levels for the luminance signal field differential absolute value data.
Assigns respective setting values to the 3-continuous codes, 4-continuous codes and 5-continuous codes
motion detection, decides data having large motion components for |∆LY| exceeding the setting, and
performs the noise attenuation compensation (YNRM = 0) or NROFF compensation (YNRM = 1).
Table R2-3-6 (1) 3-Continuous Code Motion Compensation Decision
Motion detection condition
|∆LY| > 16
Motion decision
Large (Compensation operation)
Large (Compensation operation)
Small (No compensation)
|∆LY| > YMS[3:0]
|∆LY| ≤ YMS[3:0]
Table R2-3-6 (2) 4-Continuous Code Motion Compensation Decision
Motion detection condition
|∆LY| > 8
Motion decision
Large (Compensation operation)
Large (Compensation operation)
Small (No compensation)
|∆LY| > YMS[3:1]
|∆LY| ≤ YMS[3:1]
Table R2-3-6 (3) 5-Continuous Code Motion Compensation Decision
Motion detection condition
|∆LY| > 4
Motion decision
Large (Compensation operation)
Large (Compensation operation)
Small (No compensation)
|∆LY| > YMS[3:2]
|∆LY| ≤ YMS[3:2]
AYMS[1:0] Initial value: 00; Setting range: Refer to table R2-3-5 (4).
Sets auto mode luminance motion compensation level.
Valid in the auto mode noise follow-up state.
Table R2-3-6 (4) Auto Mode Motion Compensation Level Setting
(Valid at NRAUTO = 1)
AYMS
Noise follow-up state motion compensation level
[1]
X
0
[0]
0
YMS[4:0]
1
YMAXO[5:0] (Max.: Fh)
YMAXO[5:0]/2 (Max.: Fh)
1
1