PEDL87V21071-01  
OKI Semiconductor  
ML87V21071  
(4) Auto Mode Chrominance Noise Convergence Level Settings (ACNS[1:0])  
Sets whether or not to use the chrominance noise convergence level automatic setting in the auto mode noise  
follow-up status (CDTO2 = 1).  
When AMM = 0, noise reduction stops with CDTO1 = 0, so the chrominance noise convergence level is ignored.  
Table F2-1-8 (6) Auto Mode Chrominance Noise Convergence Level Settings  
ACNS  
CBDTO  
CDTO1  
CDTO2  
Chrominance Noise Convergence Level  
[1]  
0
1
[0]  
X
0
CNS[5:0]  
CNS[5:0] + CMAXO[4:0](max:3Fh)  
Smaller of CMAXO[4:0] x 3(max:3Fh) and CNS[5:0]  
CNS[5:0]  
0
1
1
X
X
X
0
0
1
1
1
X
0
1
X
X
0
CNS[5:0]  
CNS[5:0] + CMAXO[4:0](max:3Fh)  
Larger of CMAXO[4:0] x 3(max:3Fh) and CNS[5:0]  
1
1
(5) Auto Mode Luminance Noise Upper Limit Level Settings (AYLM[1:0])  
Sets whether or not to use the luminance noise upper limit level automatic setting in the auto mode luminance  
noise follow-up status (YDTO2 = 1).  
When AMM = 0, noise reduction stops with YDTO1 = 0, so the luminance noise upper limit level is ignored.  
Table F2-1-8 (7) Auto Mode Luminance Noise Upper Limit Level Settings  
AYLM  
YBDTO  
YDTO1  
YDTO2  
Luminance noise upper limit level  
[1]  
0
1
[0]  
X
0
YLM[4:0]  
0
1
1
X
X
X
0
0
1
Smaller of YMAXO[4:0] x 0.75(max:1Fh) and YLM[4:0]  
Smaller of YMAXO[4:0](mx:1Fh) and YLM[4:0]  
YLM[4:0]  
1
1
X
0
1
X
X
0
YLM[4:0]  
Larger of YMAXO[4:0] x 0.75(max:1Fh) and YLM[4:0]  
Larger of YMAXO[4:0](max:1Fh) and YLM[4:0]  
1
1
(6) Auto Mode Chrominance Noise Upper Limit Level Settings (ACLM[1:0])  
Sets whether or not to use the chrominance noise upper limit level automatic setting in the auto mode  
chrominance noise follow-up status (CDTO2 = 1).  
When AMM = 0, noise reduction stops with CDTO1 = 0, so the chrominance noise upper limit level is ignored.  
Table F2-1-8 (8) Auto Mode Chrominance Noise Upper Limit Level Settings  
ACLM  
CBDTO  
CDTO1  
CDTO2  
Chrominance noise upper limit level  
[1]  
0
1
[0]  
X
0
CLM[4:0]  
0
1
1
X
X
X
0
0
1
Smaller of CMAXO[4:0] x 0.75 (max:1Fh) and CLM[4:0]  
Smaller of CMAXO[4:0](max:1Fh) and CLM[4:0]  
CLM[4:0]  
1
1
X
0
1
X
X
0
CLM[4:0]  
Larger of CMAXO[4:0] x 0.75(max:1Fh) and CLM[4:0]  
Larger of CMAXO[4:0](max:1Fh) and CLM[4:0]  
1
1
52/123  