FEDL63611A-01
OKI Semiconductor
ML63611A
n. Timers, counters
•
8-bit timer:
•
•
•
mode
Watchdog timer:
100 Hz timer:
15-bit TBC:
4 channels
Selectable as auto-reload mode, capture mode, clock frequency measurement
1 channel
1 channel
1/100 sec. measurement possible
1 channel
1 Hz, 2 Hz, 4 Hz, 8 Hz, 16 Hz, 32 Hz, 64 Hz, 128 Hz signals can be read
o. Serial port
•
Mode: UART mode, synchronous mode
•
Communication speed in UART mode: 1200 bps, 2400 bps, 4800 bps, 9600 bps
•
Clock frequency in synchronous mode: 32.768 kHz (internal clock mode); external clock
frequency
•
Data length: 5 to 8 bits
p. Interrupt factors
•
External interrupt (4 sources) : Selectable as rising edge/falling edge/both rising and falling
edges
•
Internal interrupt (14 sources) : Watchdog timer interrupt
×
1
Melody end interrupt
×
1
ADC interrupt
×
1
Timer interrupt
×
4
Serial port reception interrupt
×
1
Serial port transmission interrupt
×
1
1/100 timer (10 Hz) interrupt
×
1
Time base interrupt
×
4 (2, 4, 16, and 32 Hz)
q. Operating temperature
•
–20 to +70°C
r. Power supply voltage
OPTION A, OPTION B (1.5 V versions): 1.3 to 1.7 V
Note: The operation will only be at the battery voltage and no voltage halver circuit can be used.
OPTION C, OPTION D (3.0 V versions): 1.8 to 3.6 V
Note: It is possible to select by software to use the output of the halver circuit as the power supply
of the voltage regulator circuit when the battery voltage is in the range 2.4 to 3.6 V, and to
use the battery voltage itself as the power supply of the voltage regulator circuit when the
battery voltage is in the range 1.8 to 2.4 V.
It is possible to detect whether the battery voltage is 2.4 V or 1.8 V using the BLD function.
• When the halver circuit is ON: 2.4 to 3.6 V
• When the halver circuit is OFF: 1.8 to 2.4 V
4/49