FEDL5401A-02
OKI Semiconductor
ML5401A
Note 1:
The Iout range of 750mA across the four output voltages is dependent upon thermal management of the device, which includes
but not limited to proper mounting of the back side of the package to the ground plane of a minimum of 4LM board, and no less than five
vias under the device and a package with adequate PD capabilities.
Note 2 :
Line Regulation is calculated with the following expression as :
ΔV=Vout(Vin=3.6V)
- Vout ( Vin=3.0V)
LiR%= 0.5* 100*
ΔV/Vout(Vin=3.3V)
LiR% is from
–0.5%
to +0.5%.
Vout(Vin=3.6V) and Vout ( Vin=3.0V) are measured at VDD=5.0V.
Line Regulation is measured at constant junction room temperature.
Note 3 :
Load Regulation is calculated with the following expression as :
ΔVout=
Vout(Iout=10mA) - Vout(Iout=750mA)
LoR%= 100*ΔV/Vout(Iout=10mA)
LoR% is from
–0.8%
to +0.8%.
Vout(Iout=10mA) and Vout(Iout=750mA) is measured at VDD=5.0V.
Load Regulation is measured at constant junction room temperature.
Note 4 :
Current limit is the constant current mode. The current between OUTA and GND is measured when output connects ground.
- 6 / 12 -