READING STATUS  
The ML2302 supports the following seven status flags.  
Table 4.1  
Pin  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Status  
Data Recording/Playing flag  
Don’t Care  
Description  
High when recording or playback is in progress  
Pause flag  
High when playback of left voice is paused  
Don’t Care  
EMP Information Output flag  
MID Information flag  
FUL Information flag  
Data Transfer Error flag  
Output the same signal as the EMP pin. Note)  
Output the same signal as the MID pin. Note)  
Output the same signal as the FUL pin. Note)  
See “Data Transfer Errors”.  
Note: EM, MID, and FUL are either at the active “H” or at the active “L” by setting the signal output format by  
the command. The status signals on D3 to D1 are determined depending on the status of the FIFOST pin as  
shown below.  
FIFOST = “0”  
EMP signal for playback FIFO  
MID signal for playback FIFO  
FUL signal for playback FIFO  
FIFOST = “1”  
EMP signal for recording FIFO  
MID signal for recording FIFO  
FUL signal for recording FIFO  
D3  
D2  
D1  
Data Transfer Errors  
The Data Transfer flag supports the following four errors.  
(1) “H” when data is read while EMP for recording FIFO is “H”  
(2) “H” when data is written while FUL for playback FIFO is “H”  
(3) “H” when a command is written while CBUSY is “L”.  
(4) “H” when recording data cannot be written in FIFO while FUL for recording FIFO is “H”.  
*These four errors are released when a normal transfer described below is carried out.  
(1) Reads data while EMP for recording FIFO is “L”.  
(2) Writes data while FUL for playback FIFO is “L”.  
(3) Writes a command while CBUSY is “H”.  
(4) The error flag is released when data is written in recording FIFO within LSI after reading data from recording  
FIFO and setting FUL for recording FIFO to “L”.  