ODHKGL4185KD-05
KGL4185KD
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
VD1
Min
-0.3
-0.3
Max
4.0
Unit
V
Note
Supply Voltage
6.0
V
Output DC coupled 1)
Supply Voltage of Output Stage
VD2
Output AC coupled
using bias tee 2)
-0.3
4.0
V
X-Point Control and Reference Voltage
Modulation Current Control Voltage
Bias Current Control Voltage
Input Amplitude
VB1/VB2
VC1
VC2
Vin
-1.0
-1.0
-1.0
-
2.4
1.6
2.6
1.5
100
125
V
V
V
Vpp
°C
°C
AC coupled
Operating Temperature at Package Base
Storage Temperature
Ts
-10
-45
Tst
1) Refer to TYPICAL APPLICATION ( Output DC coupled ) of page 6.
2) Refer to TYPICAL APPLICATION ( Output AC coupled ) of page 7.
RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Min
3.13
4.75
Typ
3.3
5.0
Max
3.47
5.25
Unit
Note
Supply Voltage
VD1
V
V
Output DC coupled 2)
Supply Voltage of Output Stage
VD2
Output AC coupled
using bias tee 3)
3.13
3.3
3.47
V
X-Point Control Voltage
VB1
VB2 1)
VC1
0.6
1.0
0
1.2
1.8
1.4
1.2
2.4
1.2
1.2
-
V
V
X-Point Reference Voltage
Modulation Current Control Voltage
Bias Current Control Voltage
Single-ended Input Amplitude
Differential Input Amplitude
1.2
-
-
-
-
-
-
-
V
VC2
0
V
0.4
0.2
1.5
1.9
-40
Vpp
Vpp
V
AC coupled
AC coupled
Vin
Low Voltage of Modulation Current Output VL(OUT)
Low Voltage of Bias Current Output
Operating Temperature at Package Base
Input Interface
VL(BIAS)
Ts
-
V
95
°C
AC coupled (External blocking capacitor is required)
DC coupled ( Need 25 termination to VD2 )2) or
AC coupled using bias tee 3)
Output Interface
2) VB2 can be open or biased by the external circuit. For VB2 opened, VB2 is biased at about 0.364 x VD1).
3) Refer to TYPICAL APPLICATION ( Output DC coupled ) of page 6.
4) Refer to TYPICAL APPLICATION ( Output AC coupled ) of page 7.
2/12