74HC4067; 74HCT4067
NXP Semiconductors
16-channel analog multiplexer/demultiplexer
Table 5.
Recommended operating conditions …continued
Symbol Parameter
74HCT4067
Conditions
Min
Typ
Max
Unit
VCC
VI
supply voltage
input voltage
switch voltage
rise time
4.5
GND
GND
-
5.0
-
5.5
V
VCC
VCC
500
500
+125
V
VSW
tr
-
V
VCC = 4.5 V
VCC = 4.5 V
6.0
6.0
+25
ns
ns
°C
tf
fall time
-
Tamb
ambient temperature
−40
10. Static characteristics
Table 6.
RON resistance per switch for types 74HC4067 and 74HCT4067
VI = VIH or VIL; for test circuit see Figure 8.
Vis is the input voltage at a Yn or Z terminal, whichever is assigned as an input.
Vos is the output voltage at a Yn or Z terminal, whichever is assigned as an output.
For 74HC4067: VCC − GND = 2.0 V, 4.5 V, 6.0 V and 9.0 V.
For 74HCT4067: VCC − GND = 4.5 V.
Symbol
Parameter
Conditions
25 °C
Max
−40 °C to +125 °C Unit
Max Max
(85 °C) (125 °C)
Typ
RON(peak)
ON resistance (peak)
Vis = VCC to GND
[1]
[1]
[1]
VCC = 2.0 V; ISW = 100 µA
VCC = 4.5 V; ISW = 1000 µA
VCC = 6.0 V; ISW = 1000 µA
VCC = 9.0 V; ISW = 1000 µA
Vis = GND or VCC
-
-
-
-
Ω
Ω
Ω
Ω
110
95
75
180
160
130
225
200
165
270
240
195
RON(rail)
ON resistance (rail)
VCC = 2.0 V; ISW = 100 µA
VCC = 4.5 V; ISW = 1000 µA
VCC = 6.0 V; ISW = 1000 µA
VCC = 9.0 V; ISW = 1000 µA
150
90
-
-
-
160
140
120
200
175
150
240
210
180
Ω
Ω
Ω
80
70
∆RON
ON resistance mismatch Vis = VCC to GND
between channels
VCC = 2.0 V
-
-
-
-
-
-
-
-
-
-
-
-
-
Ω
Ω
Ω
Ω
VCC = 4.5 V
VCC = 6.0 V
VCC = 9.0 V
9
8
6
[1] At supply voltages (VCC − GND) approaching 2 V, the analog switch ON resistance becomes extremely non-linear. Therefore it is
recommended that these devices be used to transmit digital signals only, when using these supply voltages.
74HC_HCT4067_3
© NXP B.V. 2007. All rights reserved.
Product data sheet
Rev. 03 — 15 October 2007
9 of 29