74HC4067; 74HCT4067
NXP Semiconductors
16-channel analog multiplexer/demultiplexer
mnb047
110
(1)
R
ON
(Ω)
V
SW
90
V
CC
70
50
30
10
(2)
(3)
E
V
IL
Yn
Z
GND
V
I
SW
is
001aag733
0
1.8
3.6
5.4
7.2
9.0
V
(V)
is
Vis = 0 V to (VCC − GND)
Vis = 0 V to (VCC − GND)
(1) VCC = 4.5 V
VSW
RON
=
----------
(2) VCC = 6.0 V
(3) VCC = 9.0 V
ISW
Fig 8. Test circuit for measuring RON
Table 7. Static characteristics 74HC4067
Fig 9. Typical RON as a function of input voltage Vis
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Vis is the input voltage at a Yn or Z terminal, whichever is assigned as an input.
Vos is the output voltage at a Yn or Z terminal, whichever is assigned as an output.
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
Tamb = 25 °C
VIH
HIGH-level input voltage
LOW-level input voltage
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 9.0 V
VCC = 2.0 V
VCC = 4.5 V
VCC = 6.0 V
VCC = 9.0 V
VI = VCC or GND
VCC = 6.0 V
VCC = 10.0 V
1.5
1.2
2.4
3.2
4.7
0.8
2.1
2.8
4.3
-
V
V
V
V
V
V
V
V
3.15
-
4.2
-
6.3
-
VIL
-
-
-
-
0.5
1.35
1.80
2.70
II
input leakage current
-
-
-
-
±0.1
±0.2
µA
µA
IS(OFF)
OFF-state leakage current
VCC = 10.0 V; VI = VIH or VIL;
|VSW| = VCC − GND; see Figure 10
per channel
all channels
-
-
-
-
-
-
±0.1
±0.8
±0.8
µA
µA
µA
IS(ON)
ON-state leakage current
VCC = 10.0 V; VI = VIH or VIL;
|VSW| = VCC − GND; see Figure 11
74HC_HCT4067_3
© NXP B.V. 2007. All rights reserved.
Product data sheet
Rev. 03 — 15 October 2007
10 of 29