M29W640GH, M29W640GL, M29W640GT, M29W640GB
Maximum rating
6
Maximum rating
Stressing the device above the rating listed in the Absolute Maximum Ratings table may
cause permanent damage to the device. Exposure to Absolute Maximum Rating conditions
for extended periods may affect device reliability. These are stress ratings only and
operation of the device at these or any other conditions above those indicated in the
Operating sections of this specification is not implied. Refer also to the Numonyx SURE
Program and other relevant quality documents.
Table 14. Absolute maximum ratings
Symbol
Parameter
Temperature Under Bias
Min
Max
Unit
TBIAS
TSTG
VIO
–50
–65
125
150
°C
°C
V
Storage Temperature
Input or Output Voltage(1)(2)
Supply Voltage
–0.6
–0.6
–0.6
–0.6
VCC +0.6
4
VCC
VID
V
Identification Voltage
Program Voltage
13.5
V
(3)
VPP
13.5
V
1. Minimum voltage may undershoot to –2V during transition and for less than 20ns during transitions.
2. Maximum voltage may overshoot to VCC +2V during transition and for less than 20ns during transitions.
3. VPP must not remain at 12V for more than a total of 80hrs.
45/90