DC and AC parameters
M29W400DT, M29W400DB
(1)
Table 10. Device capacitance
Symbol
Parameter
Test Condition
Min
Max
Unit
CIN
Input capacitance
Output capacitance
VIN = 0 V
6
pF
pF
COUT
VOUT = 0 V
12
1. Sampled only, not 100% tested.
Table 11. DC characteristics
Symbol
Parameter
Test condition
Min
Max
Unit
ILI
Input Leakage current
Output Leakage current
0 V ≤VIN ≤VCC
1
1
µA
µA
ILO
0 V ≤VOUT ≤VCC
E = VIL, G = VIH,
f = 6 MHz
ICC1
Supply current (Read)
10
mA
µA
E = VCC 0.2 V,
RP = VCC 0.2 V
ICC2
Supply current (Standby)
100
Supply current
(Program/Erase)
Program/Erase
controller active
(1)
ICC3
20
mA
VIL
VIH
VOL
VOH
VID
IID
Input Low voltage
Input High voltage
Output Low voltage
Output High voltage
Identification voltage
Identification current
–0.5
0.8
V
V
0.7VCC
VCC + 0.3
0.45
IOL = 1.8 mA
V
IOH = –100 µA
VCC – 0.4
11.5
V
12.5
100
V
A9 = VID
µA
Program/Erase Lockout supply
voltage
VLKO
1.8
2.3
V
1. Sampled only, not 100% tested.
Figure 11. Read mode AC waveforms
tAVAV
VALID
A0-A17/
A–1
tAVQV
tAXQX
E
tELQV
tEHQX
tELQX
tEHQZ
G
tGLQX
tGLQV
tGHQX
tGHQZ
DQ0-DQ7/
DQ8-DQ15
VALID
tBHQV
BYTE
tELBL/tELBH
tBLQZ
AI02907
30/48