DC and AC parameters
M29W320DT, M29W320DB
7
DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 9: Operating and AC Measurement Conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 9.
Operating and AC Measurement Conditions
M29W320D
70
90
Parameter
Unit
Min
Max
Min
Max
VCC Supply Voltage
3.0
3.6
85
2.7
3.6
85
V
°C
pF
ns
V
Ambient Operating Temperature
Load Capacitance (CL)
–40
–40
30
30
Input Rise and Fall Times
Input Pulse Voltages
10
10
0 to VCC
VCC/2
0 to VCC
VCC/2
Input and Output Timing Ref. Voltages
V
Figure 8.
AC Measurement I/O Waveform
V
CC
V
/2
CC
0V
AI90196