 浏览型号M29W160ET90ZA6T的Datasheet PDF文件第14页浏览型号M29W160ET90ZA6T的Datasheet PDF文件第15页浏览型号M29W160ET90ZA6T的Datasheet PDF文件第16页浏览型号M29W160ET90ZA6T的Datasheet PDF文件第17页浏览型号M29W160ET90ZA6T的Datasheet PDF文件第19页浏览型号M29W160ET90ZA6T的Datasheet PDF文件第20页浏览型号M29W160ET90ZA6T的Datasheet PDF文件第21页浏览型号M29W160ET90ZA6T的Datasheet PDF文件第22页  
M29W160ET, M29W160EB  
Note that the Program command cannot change a  
bit set to ’0’ back to ’1’ and attempting to do so will  
set DQ5 to ‘1’. A Bus Read operation to that ad-  
dress will show the bit is still ‘0’. One of the Erase  
commands must be used to set all the bits in a  
block or in the whole memory from ’0’ to ’1’  
Erase Timer Bit (DQ3). The Erase Timer Bit can  
be used to identify the start of Program/Erase  
Controller operation during a Block Erase com-  
mand. Once the Program/Erase Controller starts  
erasing the Erase Timer Bit is set to ’1’. Before the  
Program/Erase Controller starts the Erase Timer  
Bit is set to ’0’ and additional blocks to be erased  
may be written to the Command Interface. The  
Erase Timer Bit is output on DQ3 when the Status  
Register is read.  
During Chip Erase and Block Erase operations the  
Toggle Bit changes from ’0’ to ’1’ to ’0’, etc., with  
successive Bus Read operations from addresses  
within the blocks being erased. A protected block  
is treated the same as a block not being erased.  
Once the operation completes the memory returns  
to Read mode.  
During Erase Suspend the Alternative Toggle Bit  
changes from ’0’ to ’1’ to ’0’, etc. with successive  
Bus Read operations from addresses within the  
blocks being erased. Bus Read operations to ad-  
dresses within blocks not being erased will output  
the memory cell data as if in Read mode.  
After an Erase operation that causes the Error Bit  
to be set the Alternative Toggle Bit can be used to  
identify which block or blocks have caused the er-  
ror. The Alternative Toggle Bit changes from ’0’ to  
’1’ to ’0’, etc. with successive Bus Read Opera-  
tions from addresses within blocks that have not  
erased correctly. The Alternative Toggle Bit does  
not change if the addressed block has erased cor-  
rectly.  
Alternative Toggle Bit (DQ2). The Alternative  
Toggle Bit can be used to monitor the Program/  
Erase controller during Erase operations. The Al-  
ternative Toggle Bit is output on DQ2 when the  
Status Register is read.  
Table 7. Status Register Bits  
Operation  
Program  
Address  
DQ7  
DQ6  
DQ5  
DQ3  
DQ2  
RB  
Any Address  
DQ7  
Toggle  
0
0
Program During Erase  
Suspend  
Any Address  
DQ7  
Toggle  
0
0
Program Error  
Chip Erase  
Any Address  
Any Address  
DQ7  
Toggle  
Toggle  
1
0
0
0
0
0
0
1
0
0
1
1
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
1
Toggle  
Erasing Block  
Toggle  
Toggle  
Block Erase before  
timeout  
Non-Erasing Block  
Erasing Block  
Toggle  
No Toggle  
Toggle  
Toggle  
Block Erase  
Erase Suspend  
Erase Error  
Non-Erasing Block  
Erasing Block  
Toggle  
No Toggle  
Toggle  
No Toggle  
Non-Erasing Block  
Good Block Address  
Faulty Block Address  
Data read as normal  
0
0
Toggle  
Toggle  
1
1
1
No Toggle  
Toggle  
1
Note: Unspecified data bits should be ignored.  