 浏览型号M28W160CB90N6U的Datasheet PDF文件第8页浏览型号M28W160CB90N6U的Datasheet PDF文件第9页浏览型号M28W160CB90N6U的Datasheet PDF文件第10页浏览型号M28W160CB90N6U的Datasheet PDF文件第11页浏览型号M28W160CB90N6U的Datasheet PDF文件第13页浏览型号M28W160CB90N6U的Datasheet PDF文件第14页浏览型号M28W160CB90N6U的Datasheet PDF文件第15页浏览型号M28W160CB90N6U的Datasheet PDF文件第16页  
M28W160CT, M28W160CB  
memory location must be erased and repro-  
grammed.  
See Appendix C, Figure 17, Program Flowchart  
and Pseudo Code, for the flowchart for using the  
Program command.  
cepted. The block being erased may be protected  
by issuing the Block Protect, Block Lock or Protec-  
tion Program commands. When the Program/  
Erase Resume command is issued the operation  
will complete. Only the blocks not being erased  
may be read or programmed correctly.  
Double Word Program Command  
During a Program/Erase Suspend, the device can  
be placed in a pseudo-standby mode by taking  
This feature is offered to improve the programming  
throughput, writing a page of two adjacent words  
in parallel.The two words must differ only for the  
address A0. Programming should not be attempt-  
Chip Enable to V . Program/Erase is aborted if  
IH  
Reset turns to V .  
IL  
See Appendix C, Figure 19, Program Suspend &  
Resume Flowchart and Pseudo Code, and Figure  
21, Erase Suspend & Resume Flowchart and  
Pseudo Code for flowcharts for using the Program/  
Erase Suspend command.  
ed when V is not at V  
. The command can be  
PPH  
PP  
executed if V is below V  
but the result is not  
PPH  
PP  
guaranteed.  
Three bus write cycles are necessary to issue the  
Double Word Program command.  
Program/Erase Resume Command  
The first bus cycle sets up the Double Word  
The Program/Erase Resume command can be  
used to restart the Program/Erase Controller after  
a Program/Erase Suspend operation has paused  
it. One Bus Write cycle is required to issue the  
command. Once the command is issued subse-  
quent Bus Read operations read the Status Reg-  
ister.  
Program Command.  
The second bus cycle latches the Address and  
the Data of the first word to be written.  
The third bus cycle latches the Address and the  
Data of the second word to be written and starts  
the Program/Erase Controller.  
Read operations output the Status Register con-  
tent after the programming has started. Program-  
See Appendix C, Figure 19, Program Suspend &  
Resume Flowchart and Pseudo Code, and Figure  
21, Erase Suspend & Resume Flowchart and  
Pseudo Code for flowcharts for using the Program/  
Erase Resume command.  
ming aborts if Reset goes to V . As data integrity  
IL  
cannot be guaranteed when the program opera-  
tion is aborted, the block containing the memory  
location must be erased and reprogrammed.  
See Appendix C, Figure 18, Double Word Pro-  
gram Flowchart and Pseudo Code, for the flow-  
chart for using the Double Word Program  
command.  
Protection Register Program Command  
The Protection Register Program command is  
used to Program the 64 bit user One-Time-Pro-  
grammable (OTP) segment of the Protection Reg-  
ister. The segment is programmed 16 bits at a  
time. When shipped all bits in the segment are set  
to ‘1’. The user can only program the bits to ‘0’.  
Clear Status Register Command  
The Clear Status Register command can be used  
to reset bits 1, 3, 4 and 5 in the Status Register to  
‘0’. One bus write cycle is required to issue the  
Clear Status Register command.  
The bits in the Status Register do not automatical-  
ly return to ‘0’ when a new Program or Erase com-  
mand is issued. The error bits in the Status  
Register should be cleared before attempting a  
new Program or Erase command.  
Two write cycles are required to issue the Protec-  
tion Register Program command.  
The first bus cycle sets up the Protection  
Register Program command.  
The second latches the Address and the Data to  
be written to the Protection Register and starts  
the Program/Erase Controller.  
Read operations output the Status Register con-  
tent after the programming has started.  
The segment can be protected by programming bit  
1 of the Protection Lock Register. Bit 1 of the Pro-  
tection Lock Register protects bit 2 of the Protec-  
tion Lock Register. Programming bit 2 of the  
Protection Lock Register will result in a permanent  
protection of the Security Block (see Figure 6, Se-  
curity Block and Protection Register Memory  
Map). Attempting to program a previously protect-  
ed Protection Register will result in a Status Reg-  
ister error. The protection of the Protection  
Register and/or the Security Block is not revers-  
ible.  
Program/Erase Suspend Command  
The Program/Erase Suspend command is used to  
pause a Program or Erase operation. One bus  
write cycle is required to issue the Program/Erase  
command and pause the Program/Erase control-  
ler.  
During Program/Erase Suspend the Command In-  
terface will accept the Program/Erase Resume,  
Read Array, Read Status Register, Read Electron-  
ic Signature and Read CFI Query commands. Ad-  
ditionally, if the suspend operation was Erase then  
the Program, Block Lock, Block Lock-Down or  
Protection Program commands will also be ac-  
12/50