Table 16. Operating conditions
Symbol
Parameter
Min.
Max.
Unit
VCC
TA
Supply voltage
Ambient operating temperature
2.7
3.6
85
V
–40
°C
Table 17. AC measurement conditions
Symbol
Parameter
Min.
Max.
Unit
CL
Load capacitance
30
pF
ns
V
Input rise and fall times
5
Input pulse voltages
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Input and output timing reference voltages
V
1. Output Hi-Z is defined as the point where data out is no longer driven.
Figure 26. AC measurement I/O waveform
Input levels
Input and output
timing reference levels
0.8V
CC
0.7V
0.3V
CC
CC
0.2V
CC
AI00825B
(1)
Table 18. Capacitance
Symbol
Parameter
Test condition
Min.
Max.
Unit
COUT
CIN
Output capacitance (Q)
VOUT = 0 V
VIN = 0 V
8
6
pF
pF
Input capacitance (other pins)
1. Sampled only, not 100% tested, at TA=25 °C and a frequency of 25 MHz.