DC and AC parameters
M25P16
10
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 10. Operating conditions
Symbol
Parameter
Min
Max
Unit
VCC
Supply voltage
Ambient operating temperature
2.7
–40
–40
3.6
125
85
V
grade 3
grade 6
°C
°C
TA
Table 11. Data retention and endurance
Parameter
Condition
Device grade 6
Min
Max
Unit
100 000
10 000
20
Erase/Program cycles
Data retention
Cycles per sector
years
Device grade 3
at 55 °C
Table 12. AC measurement conditions
Symbol
Parameter
Min
Max
Unit
CL
Load capacitance
30
pF
ns
V
Input rise and fall times
5
Input pulse voltages
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Input timing reference voltages
Output timing reference voltages
V
V
CC / 2
V
Figure 22. AC measurement I/O waveform
Input levels
Input and output
timing reference levels
0.8V
CC
0.7V
CC
0.5V
CC
0.3V
CC
0.2V
CC
AI07455
(1)
Table 13. Capacitance
Symbol
Parameter
Test Condition
Min
Max
Unit
COUT
CIN
Output capacitance (Q)
VOUT = 0 V
VIN = 0 V
8
6
pF
pF
Input capacitance (other pins)
1. Sampled only, not 100% tested, at TA = 25 °C and a frequency of 20 MHz.
38/55