欢迎访问ic37.com |
会员登录 免费注册
发布采购

M25P05-AVMB6P 参数 Datasheet PDF下载

M25P05-AVMB6P图片预览
型号: M25P05-AVMB6P
PDF下载: 下载PDF文件 查看货源
内容描述: 512 - Kbit的串行闪存, 50MHz的SPI总线接口 [512-Kbit, serial flash memory, 50 MHz SPI bus interface]
分类和应用: 闪存存储内存集成电路光电二极管时钟
文件页数/大小: 52 页 / 1092 K
品牌: NUMONYX [ NUMONYX B.V ]
 浏览型号M25P05-AVMB6P的Datasheet PDF文件第11页浏览型号M25P05-AVMB6P的Datasheet PDF文件第12页浏览型号M25P05-AVMB6P的Datasheet PDF文件第13页浏览型号M25P05-AVMB6P的Datasheet PDF文件第14页浏览型号M25P05-AVMB6P的Datasheet PDF文件第16页浏览型号M25P05-AVMB6P的Datasheet PDF文件第17页浏览型号M25P05-AVMB6P的Datasheet PDF文件第18页浏览型号M25P05-AVMB6P的Datasheet PDF文件第19页  
M25P05-A  
Operating features  
4.7  
Hold condition  
The Hold (HOLD) signal is used to pause any serial communications with the device without  
resetting the clocking sequence. However, taking this signal Low does not terminate any  
write status register, program or erase cycle that is currently in progress.  
To enter the hold condition, the device must be selected, with Chip Select (S) Low.  
The hold condition starts on the falling edge of the Hold (HOLD) signal, provided that this  
coincides with Serial Clock (C) being Low (as shown in Figure 5).  
The hold condition ends on the rising edge of the Hold (HOLD) signal, provided that this  
coincides with Serial Clock (C) being Low.  
If the falling edge does not coincide with Serial Clock (C) being Low, the hold condition  
starts after Serial Clock (C) next goes Low. Similarly, if the rising edge does not coincide  
with Serial Clock (C) being Low, the hold condition ends after Serial Clock (C) next goes  
Low (this is shown in Figure 5).  
During the hold condition, the Serial Data output (Q) is high impedance, and Serial Data  
input (D) and Serial Clock (C) are don’t care.  
Normally, the device is kept selected, with Chip Select (S) driven Low, for the whole duration  
of the hold condition. This is to ensure that the state of the internal logic remains unchanged  
from the moment of entering the hold condition.  
If Chip Select (S) goes High while the device is in the hold condition, this has the effect of  
resetting the internal logic of the device. To restart communication with the device, it is  
necessary to drive Hold (HOLD) High, and then to drive Chip Select (S) Low. This prevents  
the device from going back to the hold condition.  
Figure 5.  
Hold condition activation  
C
HOLD  
Hold  
Hold  
condition  
condition  
(standard use)  
(non-standard use)  
AI02029D  
15/52