 浏览型号JS28F128P30T85的Datasheet PDF文件第63页浏览型号JS28F128P30T85的Datasheet PDF文件第64页浏览型号JS28F128P30T85的Datasheet PDF文件第65页浏览型号JS28F128P30T85的Datasheet PDF文件第66页浏览型号JS28F128P30T85的Datasheet PDF文件第68页浏览型号JS28F128P30T85的Datasheet PDF文件第69页浏览型号JS28F128P30T85的Datasheet PDF文件第70页浏览型号JS28F128P30T85的Datasheet PDF文件第71页  
P30  
The user-programmable Protection Registers contain one-time programmable (OTP)  
bits; when programmed, register bits cannot be erased. Each Protection Register can  
be accessed multiple times to program individual bits, as long as the register remains  
unlocked.  
Each Protection Register has an associated Lock Register bit. When a Lock Register bit  
is programmed, the associated Protection Register can only be read; it can no longer be  
programmed. Additionally, because the Lock Register bits themselves are OTP, when  
programmed, Lock Register bits cannot be erased. Therefore, when a Protection  
Register is locked, it cannot be unlocked.  
.
Figure 31: Protection Register Map  
0x109  
128-bit Protection Register 16  
(User-Programmable)  
0x102  
0x91  
128-bit Protection Register 1  
(User-Programmable)  
0x8A  
0x89  
Lock Register 1  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
0x88  
64-bit Segment  
(User-Programmable)  
0x85  
0x84  
128-Bit Protection Register 0  
64-bit Segment  
(Factory-Programmed)  
0x81  
0x80  
Lock Register 0  
15 14 13 12 11 10  
9
8
7
6
5
4
3
2
1
0
13.3.1  
Reading the Protection Registers  
The Protection Registers can be read from any address. To read the Protection Register,  
first issue the Read Device Identifier command at any address to place the device in the  
Read Device Identifier state (see Section 9.2, “Device Commands” on page 45). Next,  
perform a read operation using the address offset corresponding to the register to be  
read. Table 33, “Device Identifier Information” on page 70 shows the address offsets of  
the Protection Registers and Lock Registers. Register data is read 16 bits at a time.  
November 2007  
Order Number: 306666-11  
Datasheet  