Numonyx™ StrataFlash® Wireless Memory (L18 AD-Mux)  
Figure 38: Protection Register Programming Flowchart  
PROTECTION REGISTER PROGRAMMING PROCEDURE  
Bus  
Operation  
Start  
Command  
Comments  
Program Data = 0xC0  
PR Setup Addr = First Location to Program  
Write  
Write  
Read  
Write 0xC0,  
PR Address  
(Program Setup)  
(Confirm Data)  
Protection Data = Data to Program  
Program Addr = Location to Program  
Write PR  
Address & Data  
None  
None  
Status Register Data.  
Read Status  
Register  
Check SR[7]:  
1 = WSM Ready  
0 = WSM Busy  
Idle  
Program Protection Register operation addresses must be  
within the Protection Register address space. Addresses  
outside this space will return an error.  
0
SR[7] =  
1
Repeat for subsequent programming operations.  
Full Status  
Check  
(if desired)  
Full Status Register check can be done after each program, or  
after a sequence of program operations.  
Write 0xFF after the last operation to set Read Array state.  
Program  
Complete  
FULL STATUS CHECK PROCEDURE  
Read Status  
Register Data  
Bus  
Operation  
Command  
Comments  
Check SR[3]:  
1 =VPP Range Error  
Idle  
Idle  
Idle  
None  
1
1
SR[3] =  
0
VPP Range Error  
Check SR[4]:  
1 =Programming Error  
None  
None  
Check SR[1]:  
1 =Block locked; operation aborted  
SR[4] =  
0
Program Error  
Only the Clear Staus Register command clears SR[1, 3, 4].  
If an error is detected, clear the Status register before  
attempting a program retry or other error recovery.  
1
Register Locked;  
Program Aborted  
SR[1] =  
0
Program  
Successful  
B.1  
Common Flash Interface (CFI)  
Common Flash Interface (CFI) is part of an overall specification for multiple command-  
set and control-interface descriptions. This appendix describes the database structure  
containing the data returned by a read operation after issuing the CFI Query command  
(see Section 9.2, “Device Commands” on page 37). System software can parse this  
November 2007  
Order Number: 313295-04  
Datasheet  
83