欢迎访问ic37.com |
会员登录 免费注册
发布采购

290702-13 参数 Datasheet PDF下载

290702-13图片预览
型号: 290702-13
PDF下载: 下载PDF文件 查看货源
内容描述: 恒忆无线闪存( W30 ) [Numonyx Wireless Flash Memory (W30)]
分类和应用: 闪存无线
文件页数/大小: 102 页 / 1400 K
品牌: NUMONYX [ NUMONYX B.V ]
 浏览型号290702-13的Datasheet PDF文件第85页浏览型号290702-13的Datasheet PDF文件第86页浏览型号290702-13的Datasheet PDF文件第87页浏览型号290702-13的Datasheet PDF文件第88页浏览型号290702-13的Datasheet PDF文件第90页浏览型号290702-13的Datasheet PDF文件第91页浏览型号290702-13的Datasheet PDF文件第92页浏览型号290702-13的Datasheet PDF文件第93页  
Numonyx™ Wireless Flash Memory (W30)  
Appendix B Common Flash Interface  
This appendix defines the data structure or database returned by the Common Flash  
Interface (CFI) Query command. System software parses this structure to gain critical  
information, such as block size, density, x8/x16, and electrical specifications.  
Once this information has been obtained, the software can determine which command  
sets to use to enable flash device writes, enable block erases, and otherwise control the  
flash device. The Query is part of an overall specification for multiple command set and  
control interface descriptions, which is called the Common Flash Interface, or CFI.  
B.1  
Query Structure Output  
The Query database allows system software to obtain information for controlling the  
flash device. This section describes the flash device CFI-compliant interface that allows  
access to Query data.  
Query data are presented on the lowest-order data outputs (DQ0-7) only. The  
numerical offset value is the address relative to the maximum bus width that the flash  
device supports. On the W30 family of flash memory devices, the Query table device  
starting address is a 10h, which is a word address for x16 flash devices.  
For a word-wide (x16) flash device, the first two Query-structure bytes, ASCII Q and R,  
appear on the low byte at word addresses 10h and 11h.  
• This CFI-compliant flash device outputs 00h data on upper bytes.  
• The flash device outputs ASCII Q in the low byte (DQ0-7) and 00h in the high byte  
(DQ8-15).  
At Query addresses containing two or more bytes of information, the least significant  
data byte is presented at the lower address, and the most significant data byte is  
presented at the higher address.  
In all of the following tables, addresses and data are represented in hexadecimal  
notation, so the h suffix has been dropped. In addition, because the upper byte of  
word-wide flash devices is always 00h, the leading 00 has been dropped from the table  
notation, and only the lower byte value is shown. Any x16 flash device outputs can be  
assumed to have 00h on the upper byte in this mode.  
Table 32: Summary of Query Structure Output as a Function of the Flash Device and Mode  
ASCI  
I
Value  
Hex  
Offset  
Hex  
Code  
Device  
00010:  
00011:  
00012:  
51  
52  
59  
Q
R
Y
Device Addresses  
November 2007  
Order Number: 290702-13  
Datasheet  
89