Typical Applications
DS008563-11
Typical Performance
DS008563-9
Regulated Output Voltage
Line Regulation (∆V
IN
= 3V)
Load Regulation (∆I
L
= 1A)
+15V
1.5 mV
15 mV
for minimum temperature drift.
R3 may be eliminated for
minimum component count.
Typical Performance
Regulated Output Voltage
Line Regulation (∆V
IN
= 3V)
Load Regulation (∆I
L
= 50 mA)
15V
1.5 mV
4.5 mV
FIGURE 4. Positive Voltage Regulator
(External NPN Pass Transistor)
FIGURE 2. Basic High Voltage Regulator
(V
OUT
= 7 to 37 Volts)
DS008563-10
Typical Performance
Regulated Output Voltage
Line Regulation (∆V
IN
= 3V)
Load Regulation (∆I
L
= 100 mA)
−15V
1 mV
2 mV
FIGURE 3. Negative Voltage Regulator
www.national.com
6