LM56
Application Hints
(Continued)
DS012893-18
FIGURE 3. Simplified Schematic
4.0 MOUNTING CONSIDERATIONS
The majority of the temperature that the LM56 is measuring
is the temperature of its leads. Therefore, when the LM56 is
placed on a printed circuit board, it is not sensing the tem-
perature of the ambient air. It is actually sensing the tem-
perature difference of the air and the lands and printed circuit
board that the leads are attached to. The most accurate tem-
perature sensing is obtained when the ambient temperature
is equivalent to the LM56’s lead temperature.
As with any IC, the LM56 and accompanying wiring and cir-
cuits must be kept insulated and dry, to avoid leakage and
corrosion. This is especially true if the cirucit may operate at
cold temperatures where condensation can occur.
Printed-circuit coatings and varnishes such as Humiseal and
epoxy paints or dips are often used to ensure that moisture
cannot corrode the LM56 or its connections.
9
www.national.com