Typical Performance Characteristics (Continued)  
Current Limit Sense Voltage  
Drift with Temperature  
Current Limit Response Time  
for Various Over Drives  
Current Limit Sense Voltage  
vs Supply Voltage  
DS008711-39  
DS008711-38  
DS008711-40  
Supply Current  
Supply Current  
Collector Current with  
Emitter Output Below Ground  
DS008711-41  
DS008711-42  
DS008711-43  
The Current Limit Sense Voltage is measured by connecting  
an adjustable 0-to-1V floating power supply in series with the  
current limit terminal and referring it to either the ground or  
the Vin terminal. Set the duty cycle to 90% and monitor test  
point TP5 while adjusting the floating power supply voltage  
until the LM1578A’s duty cycle just reaches 0%. This voltage  
is the Current Limit Sense Voltage.  
*
Test Circuit  
Parameter tests can be made using the test circuit shown.  
Select the desired Vin, collector voltage and duty cycle with  
adjustable power supplies. A digital volt meter with an input  
resistance greater than 100 Mshould be used to measure  
the following:  
Input Reference Voltage to Ground; S1 in either position.  
The Supply Current should be measured with the duty cycle  
=
=
=
=
Level Shift Accuracy (%) (TP3(V)/1V) x 100%; S1 at I1 I2  
at 0% and S1 in the I1 I2 0 mA position.  
=
1 mA  
*
LM1578A specifications are measured using automated  
=
=
=
Input Current (mA) (1V − Tp3 (V))/1 M: S1 at I1 I2  
test equipment. This circuit is provided for the customer’s  
convenience when checking parameters. Due to possible  
variations in testing conditions, the measured values from  
these testing procedures may not match those of the factory.  
0 mA.  
Oscillator parameters can be measured at Tp4 using a fre-  
quency counter or an oscilloscope.  