Electrical Characteristics
Parameter
Temperature Stability
Minimum Load Current
Current Limit
RMS Output Noise, % of
V
OUT
Ripple Rejection Ratio
Long-Term Stability
Thermal Resistance, Junction
to Case
Thermal Resistance, Junction
to Ambient (No Heat Sink)
(Continued)
Specifications with standard type face are for T
J
= 25˚C, and those with
boldface type
apply over
full Operating Tempera-
ture Range.
Unless otherwise specified, V
IN
− V
OUT
= 5V, and I
OUT
= 10 mA. (Note 2)
Conditions
Min
T
MIN
T
J
T
MAX
V
IN
− V
OUT
= 35V
V
IN
− V
OUT
10V
V
IN
− V
OUT
= 30V
10 Hz
f
10 kHz
V
OUT
= 10V, f = 120 Hz, C
ADJ
= 0 µF
V
OUT
= 10V, f = 120 Hz, C
ADJ
= 10 µF
T
J
= 125˚C, 1000 hrs
K Package
T Package
K Package
T Package
50
3
4
3.0
0.3
LM350A
Typ
1
3.5
4.5
1
0.001
65
66
86
0.25
1
66
10
3.0
0.25
Max
Min
LM350
Typ
1
3.5
4.5
1
0.001
65
86
0.25
1.2
3
35
50
1
1.5
4
10
Max
%
mA
A
A
%
dB
dB
%
˚C/W
˚C/W
˚C/W
˚C/W
Units
Note 1:
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is in-
tended to be functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics.
Note 2:
These specifications are applicable for power dissipations up to 30W for the TO-3 (K) package and 25W for the TO-220 (T) package. Power dissipation is
guaranteed at these values up to 15V input-output differential. Above 15V differential, power dissipation will be limited by internal protection circuitry. All limits (i.e.,
the numbers in the Min. and Max. columns) are guaranteed to National’s AOQL (Average Outgoing Quality Level).
Note 3:
Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating effects are
covered under the specifications for thermal regulation.
Note 4:
Refer to RETS150K drawing for military specifications of the LM150K.
Typical Performance Characteristics
Load Regulation
Current Limit
Adjustment Current
DS009061-33
DS009061-34
DS009061-35
Dropout Voltage
Temperature Stability
Minimum Operating Current
DS009061-36
DS009061-37
DS009061-38
3
www.national.com