LM323A/LM323 Electrical Characteristics
(Note 2) (Continued)
Note 1:
“Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits.
Note 2:
Unless otherwise noted, specifications apply for −55˚C
≤
T
j
≤
+150˚C for the LM123, −40˚C
≤
T
j
≤
+125˚C for the LM323A, and 0˚C
≤
T
j
≤
+125˚C for the
LM323. Although power dissipation is internally limited, specifications apply only for P
≤
30W.
Note 3:
Without a heat sink, the thermal resistance of the TO-3 package is about 35˚C/W. With a heat sink, the effective thermal resistance can only approach the
specified values of 2˚C/W, depending on the efficiency of the heat sink.
Note 4:
Load and line regulation are specified at constant junction temperature. Pulse testing is required with a pulse width
≤
1 ms and a duty cycle
≤
5%.
Note 5:
Refer to RETS123K drawing for LM123K military specifications.
Note 6:
Human body model, 1.5 kΩ in series with 100 pF.
Typical Performance Characteristics
Maximum Average Power
Dissipation for LM123
Maximum Average Power
Dissipation for LM323A, LM323
Output Impedance
DS007771-11
DS007771-9
DS007771-10
Peak Available Output Current
Short Circuit Current
Ripple Rejection
DS007771-12
DS007771-13
DS007771-14
Dropout Voltage
Line Transient Response
Output Voltage
DS007771-15
DS007771-16
DS007771-17
3