Absolute Maximum Ratings
(Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (V
CC
)
−0.3V to +4V
−0.3V to (V
CC
+ 0.3V)
Input Voltage (D
IN
)
−0.3V to (V
CC
+ 0.3V)
Enable Input Voltage (EN, EN
*
)
−0.3V to +3.9V
Output Voltage (D
OUT+
, D
OUT−
)
Short Circuit Duration
Continuous
(D
OUT+
, D
OUT−
)
Maximum Package Power Dissipation
@
+25˚C
M Package
1088 mW
MTC Package
866 mW
W Package
845 mW
Derate M Package
8.5 mW/˚C above +25˚C
Derate MTC Package
6.9 mW/˚C above +25˚C
Derate W Package
6.8 mW/˚C above +25˚C
Storage Temperature Range
Lead Temperature Range
Soldering (4 sec.)
Maximum Junction Temperature
ESD Rating (Note 10)
(HBM, 1.5 kΩ, 100 pF)
−65˚C to +150˚C
+260˚C
+150˚C
≥
6 kV
Recommended Operating
Conditions
Supply Voltage (V
CC
)
Operating Free Air
Temperature (T
A
)
Industrial
Military
Min
+3.0
Typ
+3.3
Max
+3.6
Units
V
−40
-55
+25
+25
+85
+125
˚C
˚C
Electrical Characteristics
Over supply voltage and operating temperature ranges, unless otherwise specified. (Notes 2, 3, 4)
Symbol
V
OD1
∆V
OD1
Parameter
Differential Output Voltage
Change in Magnitude of V
OD1
for Complementary Output
States
Offset Voltage
Change in Magnitude of V
OS
for
Complementary Output States
Output Voltage High
Output Voltage Low
Input Voltage High
Input Voltage Low
Input Current
Input Current
Input Clamp Voltage
Output Short Circuit Current
V
IN
V
IN
= V
CC
or 2.5V
= GND or 0.4V
D
IN
,
EN,
EN*
0.90
2.0
GND
−10
−10
−1.5
D
OUT−
D
OUT+
Conditions
R
L
= 100Ω (Figure
1)
Pin
D
OUT−
D
OUT+
Min
250
Typ
350
4
Max
450
35
Units
mV
|mV|
V
OS
∆V
OS
V
OH
V
OL
V
IH
V
IL
I
IH
I
IL
V
CL
I
OS
1.125
1.25
5
1.38
1.03
1.375
25
1.6
V
CC
0.8
V
|mV|
V
V
V
V
µA
µA
V
mA
±
1
±
1
−0.8
−6.0
+10
+10
−9.0
I
CL
= −18 mA
ENABLED, (Note 11)
D
IN
= V
CC
, D
OUT+
= 0V or
D
IN
= GND, D
OUT−
= 0V
ENABLED, V
OD
= 0V
(Note 11)
V
OUT
= 0V or 3.6V,
V
CC
= 0V or Open
EN = 0.8V and EN* = 2.0V
V
OUT
= 0V or V
CC
D
IN
= V
CC
or GND
R
L
= 100Ω All Channels, D
IN
=
V
CC
or GND (all inputs)
D
IN
= V
CC
or GND,
EN = GND, EN* = V
CC
V
CC
I
OSD
I
OFF
I
OZ
I
CC
I
CCL
I
CCZ
Differential Output Short Circuit
Current
Power-off Leakage
Output TRI-STATE Current
No Load Supply Current Drivers
Enabled
Loaded Supply Current Drivers
Enabled
No Load Supply Current Drivers
Disabled
−6.0
−20
−10
−9.0
+20
+10
8.0
30
6.0
mA
µA
µA
mA
mA
mA
±
1
±
1
5.0
23
2.6
www.national.com
2